Correlations between intraoperative and postoperative echocardiographic measurements in patients undergoing aortic bioprosthetic valve replacement: a prospective observational study
General Thoracic and Cardiovascular Surgery · 2025
DOI: 10.1007/s11748-024-02079-x ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift General Thoracic and Cardiovascular Surgery, 2025. Verfasst von Kimito Minami und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Critical Care Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan. k.minami@ncvc…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Aortic Valve, Heart Valve Prosthesis Implantation, Bioprosthesis. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Patient-prosthesis mismatch (PPM) should be avoided during surgical aortic valve replacement because PPM would worsen the mortality and morbidity. Diagnosis of PPM could be made using various parameters measured by intraoperative transesophageal echocardiography. However, few studies have examined which parameters correlate most accurately between intraoperative and postoperative values. METHODS: This single-center prospective observational study analyzed 46 patients who underwent surgical aortic valve replacement (SAVR). Echocardiography was performed at the following 3-time points: preoperatively, intraoperatively, and 1 month postoperatively. The correlation between intraoperative and postoperative measurement values, including peak velocity (PV), mean pressure gradient (MPG), effective orifice area (EOA), and effective orifice area index (EOAI), were assessed using Pearson's correlation coefficient. Moreover, to evaluate whether a multivariable linear regression model with intraoperative and postoperative stroke volume added as an explanatory variable improves the correlation, the multiple correlation coefficients were calculated. RESULTS: PV, MPG, EOA, and EOAI measured intraoperatively and 1 month postoperatively were significantly correlated. The r values of each measurement were 0.35, 0.344, 0.411 and 0.323, respectively. The multivariable linear regression model showed that the multiple correlation coefficients for MG and EOA were 0.491 and 0.663, respectively. CONCLUSION: Intraoperative and postoperative PV, MPG, EOA, and EOAI were significantly correlated in patients undergoing SAVR with a bioprosthetic valve. The r value for EOA was 0.441, the largest among the measured values. Adjustment for stroke volume improved the strength of the correlation. Intraoperative evaluation of prosthetic valve function was considered most appropriate using EOA. CLINICAL TRIAL NUMBER: University Hospital Medical Information Network Clinical Trials Registry, registration number UMIN000046164, https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000052695 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Critical Care Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan. k.minami@ncvc.go.jp.
- Department of Critical Care Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Zitieren
APA
Minami, K., & Kazawa, M. (2025). Correlations between intraoperative and postoperative echocardiographic measurements in patients undergoing aortic bioprosthetic valve replacement: a prospective observational study. General Thoracic and Cardiovascular Surgery. https://doi.org/10.1007/s11748-024-02079-x
Vancouver
Minami K, Kazawa M. Correlations between intraoperative and postoperative echocardiographic measurements in patients undergoing aortic bioprosthetic valve replacement: a prospective observational study. General Thoracic and Cardiovascular Surgery. 2025. doi:10.1007/s11748-024-02079-x
BibTeX
@article{Minami2025,
author = {Minami, Kimito and Kazawa, Masahiro},
title = {Correlations between intraoperative and postoperative echocardiographic measurements in patients undergoing aortic bioprosthetic valve replacement: a prospective observational study},
journal = {General Thoracic and Cardiovascular Surgery},
year = {2025},
doi = {10.1007/s11748-024-02079-x}
}
EUVIMED