EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Propensity score analysis of stented versus rapid deployment aortic bioprostheses in patients with small aortic annulus

Giorgia Cibin iD, Augusto D'Onofrio iD, Valentina Lombardi, Emma Bergonzoni, Giulia Lorenzoni, Elisa Gastino, Giuseppe Evangelista, Enrico Giuseppe Italiano, Irene Cao, Dario Gregori, Chiara Tessari, Gino Gerosa iD

Interdisciplinary CardioVascular and Thoracic Surgery · 2025

DOI: 10.1093/icvts/ivaf241 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Giorgia Cibin und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova 35128, Italy. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Aortic Valve, Heart Valve Prosthesis Implantation. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Haemodynamic studies have demonstrated the excellent performance of rapid deployment (RD) valves. This retrospective single-centre study aimed to compare early and medium-term outcomes of RD bioprostheses versus conventional stented valves in patients with small aortic annuli.

Methods

We included patients who underwent isolated or combined surgical aortic valve replacement (SAVR) with Magna Ease (ME) and Intuity (Edwards Lifesciences, Irvine, CA) sizes 19 and 21 at our institution between June 2016 and March 2022. Follow-up was conducted through scheduled visits and echocardiograms at the study site, or via telephonic interviews with patients and/or referring cardiologists. A propensity score weighting analysis was performed to account for baseline differences between the 2 cohorts.

Results

A total of 666 consecutive patients underwent SAVR with the 2 devices. ME was implanted in 367 patients (55.1%) and Intuity in 299 (44.9%). ME size 19 or 21 was used in 105 patients (35.1%), and Intuity size 19 or 21 in 115 patients (31.3%). Our study population comprised 220 patients. There were no significant differences in postoperative complications. Intuity demonstrated significantly lower gradients overall (mean gradients: 12 mmHg vs 16 mmHg, P < 0.001) and for size 21 (mean gradients: 12 mmHg vs 15 mmHg, P < 0.001). Mid-term survival and rehospitalization rates were similar between the 2 devices (5-year rehospitalization rate: 17% ME vs 20.9% Intuity, P = 0.57; 5-year survival: 81.9% ME vs 88% Intuity, P = 0.761).

Conclusions

In patients with small aortic annuli, RD bioprostheses provide superior haemodynamic outcomes compared to conventional stented valves. However, perioperative outcomes, mid-term survival, and rehospitalization rates are similar between the 2 devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BioprosthesisHeart Valve ProsthesisAortic ValveHeart Valve Prosthesis ImplantationStentsAortic Valve StenosisHumansMaleFemaleRetrospective StudiesPropensity ScoreAgedProsthesis DesignTreatment OutcomeMiddle AgedTime FactorsAged, 80 and overHemodynamicsPostoperative ComplicationsRisk Factors

Stichwörter der Autor:innen

rapid-deployment valvesmall anulusstented aortic valvesurgical aortic valve replacement

Autor:innen und Institutionen

  • Division of Cardiac Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova 35128, Italy.
  • Division of Cardiac Surgery, University of Roma "Tor Vergata", Rome 00133, Italy.
  • Unit of Biostatistics, Epidemiology and Public Health, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova 35128, Italy.
  • Division of Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Milano 20097, Italy.

ORCID-Profile: Giorgia Cibin, Augusto D'Onofrio, Gino Gerosa

Zitieren

APA

Cibin, G., D'Onofrio, A., Lombardi, V., Bergonzoni, E., Lorenzoni, G., Gastino, E., Evangelista, G., Italiano, E. G., Cao, I., Gregori, D., Tessari, C., & Gerosa, G. (2025). Propensity score analysis of stented versus rapid deployment aortic bioprostheses in patients with small aortic annulus. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf241

Vancouver

Cibin G, D'Onofrio A, Lombardi V, Bergonzoni E, Lorenzoni G, Gastino E, et al. Propensity score analysis of stented versus rapid deployment aortic bioprostheses in patients with small aortic annulus. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf241

BibTeX
@article{Cibin2025,
  author = {Cibin, Giorgia and D'Onofrio, Augusto and Lombardi, Valentina and Bergonzoni, Emma and Lorenzoni, Giulia and Gastino, Elisa and Evangelista, Giuseppe and Italiano, Enrico Giuseppe and Cao, Irene and Gregori, Dario and Tessari, Chiara and Gerosa, Gino},
  title = {Propensity score analysis of stented versus rapid deployment aortic bioprostheses in patients with small aortic annulus},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2025},
  doi = {10.1093/icvts/ivaf241}
}
Kostenlos starten →