Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping
Europace · 2026
DOI: 10.1093/europace/euag118 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2026. Verfasst von Daniel Rodríguez-Muñoz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Hospital Universitario 12 de Octubre, Avda. de Córdoba s/n, Madrid 28041, Spain. Hauptthemen laut MEDLINE: Pulmonary Veins, Workflow, Catheter Ablation, Atrial Fibrillation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Boston Scientific Inc.
Abstract (Originalsprache)
Aims
Real-world series report substantial rates of pulmonary vein (PV) reconnection following index procedure with a pentaspline pulsed-field ablation (P-PFA) catheter. The contrast with initial durability data suggests this may be due to limitations in procedural workflow. Methods and results We conducted a single-centre, prospective study including consecutive patients undergoing first-time P-PFA pulmonary vein isolation (PVI), subsequently scheduled for systematic invasive remapping ≥30 days after the index procedure. Workflow was progressively refined in three phases, aiming at ensuring adequate tissue contact and based on previous remapping findings. The primary endpoint was PVI durability, per vein and per patient. Of 118 enrolled patients, 94 (Phase 1:n = 30; Phase 2:n = 34; Phase 3:n = 30) underwent systematic remapping, where 13, 10, and 1 reconnected PVs were observed in Phases 1, 2, and 3, respectively. This resulted in per-vein durability of 89.8%, 92.9%, and 99.2% (P = 0.005) and per-patient durability of 60.0%, 76.5%, and 96.7% (P = 0.004). Mean total PFA applications increased from 36.8 ± 5.2 in Phase 1 to 52.1 ± 8.0 and 58.7 ± 15.1 in Phases 2 and 3, respectively (P < 0.001). Median procedure time rose from 43 (39–50) minutes in Phase 1 to 46 (42–56) minutes in Phase 2 and 69 (61–77) minutes in Phase 3 (P < 0.001), with significant parallel increases in LA dwell time (P < 0.001) across phases. No major or minor complications occurred during index or remapping procedures.
Conclusion
Progressive workflow refinements for pentaspline P-PFA markedly improved PVI durability to nearly 100%, supporting the concept that PV reconnection is predominantly technique-dependent rather than intrinsic to catheter or waveform design.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Cardiology Department, Hospital Universitario 12 de Octubre, Avda. de Córdoba s/n, Madrid 28041, Spain.
- Instituto de Investigación Hospital 12 de Octubre (imas12), Avda. de Córdoba s/n, Madrid 28041, Spain.
- Cardiology Department, Hospital Universitario de Getafe, Getafe, Spain.
- Department of Medicine, Faculty of Medicine, Universidad Complutense, Madrid, Spain.
- Centro de Investigación Biomédica en Red de Enfermedades CardioVasculares (CIBERCV), Instituto de Salud Carlos III (ISCIII), Madrid, Spain.
ORCID-Profile: Daniel Rodríguez-Muñoz, Lucía Cobarro Gálvez, Ez Alddin Rajjoub Al-Mahdi, Isabel López-Alacid, Javier Ramos Jiménez, Álvaro Marco Del Castillo, Luis Borrego Bernabé, Martín Negreira Caamaño, Lorena Gómez Burgueño, Fernando Arribas Ynsaurriaga, Rafael Salguero-Bodes
Förderung
- Boston Scientific Inc
Zitieren
APA
Rodríguez-Muñoz, D., Cobarro Gálvez, L., Rajjoub Al-Mahdi, E. A., López-Alacid, I., Ramos Jiménez, J., Marco Del Castillo, Á., Borrego Bernabé, L., Negreira Caamaño, M., Gómez Burgueño, L., Arribas Ynsaurriaga, F., & Salguero-Bodes, R. (2026). Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping. Europace. https://doi.org/10.1093/europace/euag118
Vancouver
Rodríguez-Muñoz D, Cobarro Gálvez L, Rajjoub Al-Mahdi EA, López-Alacid I, Ramos Jiménez J, Marco Del Castillo Á, et al. Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping. Europace. 2026. doi:10.1093/europace/euag118
BibTeX
@article{RodrguezMuoz2026,
author = {Rodríguez-Muñoz, Daniel and Cobarro Gálvez, Lucía and Rajjoub Al-Mahdi, Ez Alddin and López-Alacid, Isabel and Ramos Jiménez, Javier and Marco Del Castillo, Álvaro and Borrego Bernabé, Luis and Negreira Caamaño, Martín and Gómez Burgueño, Lorena and Arribas Ynsaurriaga, Fernando and Salguero-Bodes, Rafael},
title = {Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping},
journal = {Europace},
year = {2026},
doi = {10.1093/europace/euag118}
}
EUVIMED