Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation
Europace · 2026
DOI: 10.1093/europace/euag244 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Europace, 2026. Verfasst von Daniel Rodríguez Muñoz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Hospital Universitario 12 de Octubre, Glorieta de Malaga 11, 28041 Madrid, Spain. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation, Electrophysiologic Techniques, Cardiac. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Abbott.
Abstract (Originalsprache)
Aims
Data on long-term durability of pulmonary vein isolation (PVI) with newer pulsed field ablation (PFA) platforms and incremental value of electroanatomic mapping (EAM) guidance remain limited. This study evaluated chronic PVI durability following ablation with a balloon-in-basket PFA catheter and compared outcomes of fluoroscopy-only vs. fluoroscopy plus EAM workflows. Methods and results In this prospective, single-centre trial, consecutive patients with paroxysmal or persistent atrial fibrillation (AF) underwent de novo PVI with a balloon-in-basket PFA catheter. Patients were randomized 1:1 to fluoroscopy-only or fluoroscopy plus EAM workflow. Systematic invasive remapping was planned >30 days after the index procedure. The dual primary efficacy endpoint was the proportion of pulmonary veins (PVs) and of patients with all PVs durably isolated. The prespecified secondary endpoint was the comparison of procedural characteristics and PVI durability between workflows. Safety outcomes included major adverse events within 30 days of index or remapping procedures. Ninety-six patients (67.4 ± 9.2 years, 44.8% female, 57.3% with paroxysmal AF) underwent index ablation. Fluoroscopy time and number of applications were 3.4 [2.4–4.6] minutes and 15 [13–16], respectively. Systematic remapping was performed in 86 patients at a median of 41 days, with per-vein and per-patient durability of 341/350 (97.4%), and 79/86 (91.9%) respectively. PVI durability and chronic remapping parameters were comparable between guidance strategies. No major adverse events occurred.
Conclusion
A standardized balloon-in-basket PFA workflow for PVI achieved high PVI durability. EAM guidance did not confer additional procedural or durability benefit over fluoroscopy-only guidance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Department, Hospital Universitario 12 de Octubre, Glorieta de Malaga 11, 28041 Madrid, Spain.
- Instituto de Investigación Hospital 12 de Octubre (imas12), Glorieta de Malaga 11, 28041 Madrid, Spain.
- Department of Medicine, Universidad Complutense, Madrid, Spain.
- Centro de Investigación Biomédica en Red de enfermedades CardioVasculares (CIBERCV), Instituto de Salud Carlos III (ISCIII), Madrid, Spain.
ORCID-Profile: Daniel Rodríguez Muñoz, Isabel López-Alacid, Lucía Cobarro Gálvez, Ez Alddin Rajjoub Al-Mahdi, Álvaro Marco Del Castillo, Javier Ramos Jiménez, Luis Borrego Bernabé, Fernando Arribas Ynsaurriaga, Rafael Salguero-Bodes
Förderung
- Abbott
Zitieren
APA
Rodríguez Muñoz, D., López-Alacid, I., Cobarro Gálvez, L., Rajjoub Al-Mahdi, E. A., Marco Del Castillo, Á., Ramos Jiménez, J., Borrego Bernabé, L., Arribas Ynsaurriaga, F., & Salguero-Bodes, R. (2026). Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation. Europace. https://doi.org/10.1093/europace/euag244
Vancouver
Rodríguez Muñoz D, López-Alacid I, Cobarro Gálvez L, Rajjoub Al-Mahdi EA, Marco Del Castillo Á, Ramos Jiménez J, et al. Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation. Europace. 2026. doi:10.1093/europace/euag244
BibTeX
@article{RodrguezMuoz2026,
author = {Rodríguez Muñoz, Daniel and López-Alacid, Isabel and Cobarro Gálvez, Lucía and Rajjoub Al-Mahdi, Ez Alddin and Marco Del Castillo, Álvaro and Ramos Jiménez, Javier and Borrego Bernabé, Luis and Arribas Ynsaurriaga, Fernando and Salguero-Bodes, Rafael},
title = {Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation},
journal = {Europace},
year = {2026},
doi = {10.1093/europace/euag244}
}
EUVIMED