EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieVergleichsstudieOpen Access · CC BY 4.0

Lattice-tip vs. standard irrigated focal-tip catheter for radiofrequency ablation of the cavotricuspid isthmus - the LINEAR randomized trial

Stylianos Tzeis iD, Dimitrios Asvestas iD, Vasileios Sousonis iD, Emmanouil Vavouris, Paschalis Karakasis iD, Dimitrios Charitos iD, Stavros Karanikas iD, Konstantinos Pamporis iD, Panos Vardas iD, Konstantinos Vlachos iD

Europace · 30.03.2026 · 28 (4)

DOI: 10.1093/europace/euag046 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Europace, online erschienen am 14.04.2026. Verfasst von Stylianos Tzeis und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Mitera Hospital, 6 Erythtrou Stavrou str, 151 23, Marousi, Athens, Greece. Hauptthemen laut MEDLINE: Catheter Ablation, Atrial Flutter, Tricuspid Valve, Therapeutic Irrigation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Cavotricuspid isthmus (CTI) ablation is a cornerstone therapy for typical atrial flutter (AFl) and is commonly performed during atrial fibrillation (AF) ablation. In this multicentre randomized trial, we compared a lattice-tip catheter with an irrigated focal-tip catheter for radiofrequency CTI ablation (LINEAR study—ClinicalTrials.gov NCT07078760). Methods and results Patients were randomized to a lattice-tip, dual-energy catheter (lattice-tip group) or to a standard 3.5-mm irrigated radiofrequency catheter (standard group) in two centres. In the lattice-tip group, only radiofrequency was utilized. The primary endpoint was the achievement and persistence of bidirectional CTI block after a 60-minute waiting period, confirmed by high-density electroanatomical mapping and adenosine testing. Secondary endpoints included the rate of first-pass block, the number of lesions, and the ablation time. Procedural complications were recorded. In total, 102 patients were randomized. The primary endpoint was achieved in significantly more patients in the lattice-tip as compared to the standard group (94.1% vs. 68.6%, P = 0.002). The lattice-tip catheter resulted in a significantly higher rate of first-pass block (90.2% vs. 60.8%, P = 0.001). CTI block required significantly shorter ablation time (41.3 ± 12.1 vs. 245.3 ± 91.3 s, P < 0.001) and a significantly lower number of lesions (8.3 ± 2.4 vs. 13.4 ± 4.5, P < 0.001) in the lattice-tip as compared to the standard group. No procedural complications were documented.

Conclusion

The lattice tip catheter resulted in higher acute procedural success for radiofrequency CTI ablation compared to the standard irrigated focal-tip catheter. Future studies are needed to assess long-term efficacy and clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationAtrial FlutterTricuspid ValveTherapeutic IrrigationCardiac CathetersAtrial FibrillationHumansTreatment OutcomeEquipment DesignFemaleMaleAgedTime Factors

Stichwörter der Autor:innen

Atrial flutterCatheter ablationCavotricuspid isthmusIrrigated-tip catheterLattice-tip catheter

Autor:innen und Institutionen

  • Department of Cardiology, Mitera Hospital, 6 Erythtrou Stavrou str, 151 23, Marousi, Athens, Greece.
  • 7th Cardiology Department, Hygeia Hospital, Athens, Greece.

ORCID-Profile: Stylianos Tzeis, Dimitrios Asvestas, Vasileios Sousonis, Paschalis Karakasis, Dimitrios Charitos, Stavros Karanikas, Konstantinos Pamporis, Panos Vardas, Konstantinos Vlachos

Zitieren

APA

Tzeis, S., Asvestas, D., Sousonis, V., Vavouris, E., Karakasis, P., Charitos, D., Karanikas, S., Pamporis, K., Vardas, P., & Vlachos, K. (2026). Lattice-tip vs. standard irrigated focal-tip catheter for radiofrequency ablation of the cavotricuspid isthmus - the LINEAR randomized trial. Europace, 28(4). https://doi.org/10.1093/europace/euag046

Vancouver

Tzeis S, Asvestas D, Sousonis V, Vavouris E, Karakasis P, Charitos D, et al. Lattice-tip vs. standard irrigated focal-tip catheter for radiofrequency ablation of the cavotricuspid isthmus - the LINEAR randomized trial. Europace. 2026;28(4). doi:10.1093/europace/euag046

BibTeX
@article{Tzeis2026,
  author = {Tzeis, Stylianos and Asvestas, Dimitrios and Sousonis, Vasileios and Vavouris, Emmanouil and Karakasis, Paschalis and Charitos, Dimitrios and Karanikas, Stavros and Pamporis, Konstantinos and Vardas, Panos and Vlachos, Konstantinos},
  title = {Lattice-tip vs. standard irrigated focal-tip catheter for radiofrequency ablation of the cavotricuspid isthmus - the LINEAR randomized trial},
  journal = {Europace},
  year = {2026},
  volume = {28},
  number = {4},
  doi = {10.1093/europace/euag046}
}
Kostenlos starten →