Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16516 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Hidehiro Iwakawa und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan. Hauptthemen laut MEDLINE: Catheter Ablation, Tricuspid Valve, Cardiac Catheters, Education, Medical, Graduate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: This study (ex-vivo section) was partially supported by JSPS Grants-in-Aid for Scientific Research (22K16068)..
Abstract (Originalsprache)
Introduction
The suitability of high‐power short‐duration (HPSD) cavo‐tricuspid isthmus ablation (CTI‐Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI‐Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate‐power long duration (MPLD) ablations.
Methods
Study 1: CTI‐Abl was performed by first‐ to fourth‐year EP trainees in consecutive 113 patients (67 ± 11 years, 27.2% female). Study cohort was historically divided into three groups: MPLD (30–35 W for up to 30 s) using TactiCath (TC‐MPLD, N = 38) and MPLD and HPSD (50 W for 12 s) using TactiFlex (TF‐MPLD, N = 23; TF‐HPSD, N = 52). Primary endpoint was first‐pass bidirectional isthmus block (BIB). Study 2: lesion geometries created by each ablation strategy were compared using an ex‐vivo model.
Results
Study 1: TF‐HPSD ablation strategy demonstrated a higher success rate of first‐pass BIB than MPLD protocol (TC‐MPLD, 58%; TF‐MPLD, 48%; TF‐HPSD, 94%, p < 0.001), without any complications. TF‐HPSD group was associated with shorter total procedure and RF application times, as well as fewer ablation points and gaps, compared to the MPLD groups. Study 2: TF‐HPSD created greater lesion surface length, width, and area than MPLD strategies.
Conclusion
HPSD CTI‐Abl performed by EP trainees using TactiFlex SE catheter demonstrated a higher first‐pass BIB rate, shorter total procedure and RF application times, and fewer ablation points and gaps compared to the conventional method, without increasing complication rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
- Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan.
ORCID-Profile: Hidehiro Iwakawa, Masateru Takigawa, Takatoshi Shigeta, Tomomasa Takamiya, Masahiko Goya, Tetsuo Sasano
Förderung
- This study (ex-vivo section) was partially supported by JSPS Grants-in-Aid for Scientific Research (22K16068).
Zitieren
APA
Iwakawa, H., Takigawa, M., Nakada, K., Yamamoto, T., Ikenouchi, T., Masumura, M., Negishi, M., Kawamura, I., Goto, K., Shigeta, T., Nishimura, T., Takamiya, T., Tao, S., Miyazaki, S., Goya, M., Watanabe, H., & Sasano, T. (2025). Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16516
Vancouver
Iwakawa H, Takigawa M, Nakada K, Yamamoto T, Ikenouchi T, Masumura M, et al. Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16516
BibTeX
@article{Iwakawa2025,
author = {Iwakawa, Hidehiro and Takigawa, Masateru and Nakada, Kosuke and Yamamoto, Tasuku and Ikenouchi, Takashi and Masumura, Mayumi and Negishi, Miho and Kawamura, Iwanari and Goto, Kentaro and Shigeta, Takatoshi and Nishimura, Takuro and Takamiya, Tomomasa and Tao, Susumu and Miyazaki, Shinsuke and Goya, Masahiko and Watanabe, Hiroyuki and Sasano, Tetsuo},
title = {Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16516}
}
EUVIMED