EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Outcomes for patients implanted with a cardioverter-defibrillator at <19 years of age: a Swedish national study

Camilla Wirestrand, Fredrik Gadler iD, Annika Rydberg iD, Anders Nygren iD, André Rudolph iD, Anna Wålinder Österberg iD, Eva Fernlund iD, Ida Jeremiasen iD, Ingegerd Östman-Smith iD, Jenny Alenius Dahlqvist iD, Håkan Eliasson iD

Europace · 2026

DOI: 10.1093/europace/euaf317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, 2026. Verfasst von Camilla Wirestrand und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Women's and Children's Health, Karolinska Institutet, Tomtebodavãgen 18A, 17177 Solna, Sweden. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Electric Countershock, Death, Sudden, Cardiac, Arrhythmias, Cardiac. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Samariten Foundation, Swedish ICD and Pacemaker Registry.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To explore the prevalence and incidence of paediatric implantable cardioverter-defibrillator (ICD) patients in Sweden and identify risk factors associated with appropriate shocks and adverse events. Methods and results We performed a nationwide, retrospective cohort study of ICD use in paediatric patients (<19 years) between 1995 and 2017; 120 patients underwent ICD implantation at median age 14.7 (range 1.1–18.9) years and were followed for 7.1 (0.3–20.4) years. Fifty-four patients (45%) received a primary preventive ICD; 46% had cardiomyopathy, and 41% had primary electrical disease. The estimated 5-year survival without appropriate shocks was 68% (confidence interval 59–78). Secondary preventive ICDs and lower weight (<30 kg) at implantation were associated with a higher rate of appropriate shocks, respectively. Lower weight at implantation was not a risk factor for adverse events. Inadequate medication and insufficient compliance were common in patients who experienced shocks. Less than half (46%) of the cases with inappropriate shocks were adequately medicated with good compliance. Secondly, an incidence and prevalence study of all paediatric and adult patients who had an ICD implanted in Sweden was analysed in 4-year periods between 2002 and 2021. The incidence of paediatric ICD implantations in Sweden peaked at 0.56 per 100 000 person-years in 2010–13, decreasing to 0.45 per 100 000 person-years in the last study period (2018–21).

Conclusion

Appropriate shocks were more than twice as common in the youngest patient group, whereas adverse events were not more frequent than in the older patient group. Inadequate medication and lack of compliance were common in connection with ICD shocks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableElectric CountershockDeath, Sudden, CardiacArrhythmias, CardiacHumansSwedenMaleFemaleChildAdolescentRetrospective StudiesChild, PreschoolRisk FactorsInfantPrevalenceIncidenceTreatment OutcomeAge FactorsTime FactorsYoung AdultPrimary PreventionSecondary Prevention

Stichwörter der Autor:innen

Cardiac arrhythmiasChildrenImplantable cardioverter-defibrillatorSudden cardiac death

Autor:innen und Institutionen

  • Department of Women's and Children's Health, Karolinska Institutet, Tomtebodavãgen 18A, 17177 Solna, Sweden.
  • Department of Medicine, Karolinska Institutet, Stockholm, Sweden.
  • Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden.
  • Department of Clinical Sciences, Pediatrics, Umea University, Umea, Sweden.
  • Department of Pediatric Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Pediatric Cardiology Stockholm-Uppsala, Karolinska University Hospital, Eugeniavãgen 23, Solna SE-171 64, Sweden.

ORCID-Profile: Fredrik Gadler, Annika Rydberg, Anders Nygren, André Rudolph, Anna Wålinder Österberg, Eva Fernlund, Ida Jeremiasen, Ingegerd Östman-Smith, Jenny Alenius Dahlqvist, Håkan Eliasson

Förderung

  • Samariten Foundation
  • Swedish ICD and Pacemaker Registry

Zitieren

APA

Wirestrand, C., Gadler, F., Rydberg, A., Nygren, A., Rudolph, A., Wålinder Österberg, A., Fernlund, E., Jeremiasen, I., Östman-Smith, I., Alenius Dahlqvist, J., & Eliasson, H. (2026). Outcomes for patients implanted with a cardioverter-defibrillator at. Europace. https://doi.org/10.1093/europace/euaf317

Vancouver

Wirestrand C, Gadler F, Rydberg A, Nygren A, Rudolph A, Wålinder Österberg A, et al. Outcomes for patients implanted with a cardioverter-defibrillator at. Europace. 2026. doi:10.1093/europace/euaf317

BibTeX
@article{Wirestrand2026,
  author = {Wirestrand, Camilla and Gadler, Fredrik and Rydberg, Annika and Nygren, Anders and Rudolph, André and Wålinder Österberg, Anna and Fernlund, Eva and Jeremiasen, Ida and Östman-Smith, Ingegerd and Alenius Dahlqvist, Jenny and Eliasson, Håkan},
  title = {Outcomes for patients implanted with a cardioverter-defibrillator at},
  journal = {Europace},
  year = {2026},
  doi = {10.1093/europace/euaf317}
}
Kostenlos starten →