EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC 4.0

Evolution of implantable cardioverter–defibrillator shock therapy in children in the era of optimized ICD programming and remote monitoring

Robin A Bertels iD, Eric Boersma iD, Martijn D Zeggelaar, Sophie A F van Dongen, Arend D J Ten Harkel, Lieselot van Erven iD, Cynthia Smeding, Beatrijs Bartelds iD, Gert van den Berg iD, Ewout P Boesaard iD, Rohit E Bhagwandien, Sing-Chien Yap iD und 3 weitere

Europace · 2025

DOI: 10.1093/europace/euaf240 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Europace, 2025. Verfasst von Robin A Bertels und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Willem-Alexander Children's Hospital-Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, Leiden 2300…. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Death, Sudden, Cardiac, Electric Countershock, Remote Sensing Technology. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Dutch Hartekind Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Implantable cardioverter defibrillator (ICD) therapy is effective in preventing sudden cardiac death in children. Unnecessary shocks should be avoided. ICD programming strategies and remote monitoring have been proven to be effective in preventing ICD shock therapy in adults; the present study evaluates the effectiveness in children. Methods and results Retrospective multi-centre study, including children with transvenous or epicardial ICD implantation. During follow-up data on ICD shocks, programming variables and remote monitoring were collected. One hundred sixteen children were included, median age 13.4 years (min–max 0.3–18) and median follow-up 5.2 years (IQR 3.7–6.6), 53 with an ICD implanted before 2010 and 63 after 2010. The total appropriate and inappropriate annual shock rate decreased from 10.5 to 8% [difference in mean cumulative function (MCF) P = 0.008], 7.8 to 5.8% (MCF P = 0.036), and 4.3 to 2.6% (MCF P = 0.28), respectively, without increase in cardiac-related death. Remote monitoring was associated with a decrease of total shocks (MCF P = 0.013) and appropriate shocks (MCF P = 0.052). The ventricular fibrillation (VF) zone was programmed higher (≥210 bpm) at the time of appropriate vs. inappropriate shocks (86 vs. 79%; P = 0.0016), with no significant change in VF zone programming after 2010 compared to before 2010 (90 vs. 76%; P = 0.142) and in patients with vs. without shocks (79 vs. 89%; P = 0.243).

Conclusion

The incidence of ICD shocks has significantly decreased in children with implantation after 2010, which appears to be multifactorial. A changed programming behaviour and remote monitoring are associated with this decrease and support its use in strategies to prevent unnecessary shocks in children.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableDeath, Sudden, CardiacElectric CountershockRemote Sensing TechnologyHumansChildRetrospective StudiesFemaleMaleAdolescentChild, PreschoolTreatment OutcomeInfantTime FactorsRisk Factors

Stichwörter der Autor:innen

ChildrenICD programmingImplantable cardioverter–defibrillatorRemote monitoringVF zone

Autor:innen und Institutionen

  • Department of Pediatric Cardiology, Willem-Alexander Children's Hospital-Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, Leiden 2300 RC, the Netherlands.
  • Thorax Center, Department of Cardiology, Erasmus Medical Center, Cardiovascular Institute, Dr. Molewaterplein 40, Rotterdam, the Netherlands.
  • Cardiovascular Institute, Department of Pediatric Cardiology, Erasmus Medical Center-Sophia Children's Hospital, Dr. Molewaterplein 40, Rotterdam, the Netherlands.
  • Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, Leiden, the Netherlands.
  • Department of Pediatric Cardiology, Radboud University Medical Center-Amalia Children's Hospital, Geert Grooteplein Zuid 10, Nijmegen, the Netherlands.
  • Department of Cardiology, Amsterdam University Medical Centers, Meibergdreef 9, Amsterdam, the Netherlands.

ORCID-Profile: Robin A Bertels, Eric Boersma, Lieselot van Erven, Beatrijs Bartelds, Gert van den Berg, Ewout P Boesaard, Sing-Chien Yap, Reinoud E Knops, Nico A Blom, Janneke A E Kammeraad

Förderung

  • Dutch Hartekind Foundation

Zitieren

APA

Bertels, R. A., Boersma, E., Zeggelaar, M. D., van Dongen, S. A. F., Ten Harkel, A. D. J., van Erven, L., Smeding, C., Bartelds, B., van den Berg, G., Boesaard, E. P., Bhagwandien, R. E., Yap, S. C., Knops, R. E., Blom, N. A., & Kammeraad, J. A. E. (2025). Evolution of implantable cardioverter–defibrillator shock therapy in children in the era of optimized ICD programming and remote monitoring. Europace. https://doi.org/10.1093/europace/euaf240

Vancouver

Bertels RA, Boersma E, Zeggelaar MD, van Dongen SAF, Ten Harkel ADJ, van Erven L, et al. Evolution of implantable cardioverter–defibrillator shock therapy in children in the era of optimized ICD programming and remote monitoring. Europace. 2025. doi:10.1093/europace/euaf240

BibTeX
@article{Bertels2025,
  author = {Bertels, Robin A and Boersma, Eric and Zeggelaar, Martijn D and van Dongen, Sophie A F and Ten Harkel, Arend D J and van Erven, Lieselot and Smeding, Cynthia and Bartelds, Beatrijs and van den Berg, Gert and Boesaard, Ewout P and Bhagwandien, Rohit E and Yap, Sing-Chien and Knops, Reinoud E and Blom, Nico A and Kammeraad, Janneke A E},
  title = {Evolution of implantable cardioverter–defibrillator shock therapy in children in the era of optimized ICD programming and remote monitoring},
  journal = {Europace},
  year = {2025},
  doi = {10.1093/europace/euaf240}
}
Kostenlos starten →