EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY 4.0

Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden

Amar Taha, Anna Slättman, Emanuele Bobbio, Kamal Hamidi, Andreas Martinsson, Uzma Chaudhry, Marina M Demidova, Arash Mokhtari, Christian L Polte, Piotr Szamlewski, Entela Bollano, Pyotr G Platonov

Heart Rhythm · 2026

DOI: 10.1016/j.hrthm.2026.07.014 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Heart Rhythm, 2026. Verfasst von Amar Taha und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department o…. Hauptthemen laut MEDLINE: Cardiomyopathies, Defibrillators, Implantable, Prosthesis-Related Infections, Sarcoidosis. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Swedish Heart Lung Foundation, Skåne University Hospital Lund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Cardiac sarcoidosis (CS) can cause arrhythmias and heart failure, often requiring cardiac implantable electronic devices (CIEDs). The 2014 Heart Rhythm Society consensus strengthened implantable cardioverter-defibrillator (ICD) recommendations in CS, potentially affecting practice patterns. Immunosuppressive therapy, central to CS management, may increase CIED infection risk. OBJECTIVE: To evaluate 30-year trends in CIED use in CS and the association between immunosuppression timing and 1-year infection risk. METHODS: This retrospective cohort study included patients with CS who received a CIED at 2 Swedish tertiary centers between 1994 and 2023. Device type and indications were compared before and after the 2014 Heart Rhythm Society consensus (1994-2014 vs 2015-2023). CIED infection rates were analyzed according to immunosuppression initiation (>10 days after implantation vs within or before 10 days). RESULTS: Among 212 patients diagnosed with CS, 140 (66.0%) received a CIED and were included in this study. ICDs were the first implanted device in 70.7% of patients, increasing from 66.0% to 73.6% before and after 2014, respectively, and 59.7% were for primary prevention. The mean interval from CS diagnosis to CIED implantation significantly shortened after 2014 (-1.5 vs 0.1 years, P = .037), suggesting earlier diagnosis relative to CIED implantation. The overall CIED infection rate was 6.4% (n = 9), 7.5% in patients with delayed and 5% in those with early-initiated immunosuppression. CONCLUSION: In CS, early recognition and ICD utilization, particularly for primary prevention, have increased. CIED infection rates were similar regardless of the timing of immunosuppression initiation relative to CIED implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CardiomyopathiesDefibrillators, ImplantableProsthesis-Related InfectionsSarcoidosisAgedFemaleHumansMaleMiddle AgedFollow-Up StudiesIncidenceRetrospective StudiesRisk AssessmentRisk FactorsSwedenTime Factors

Stichwörter der Autor:innen

Cardiac implantable electronic deviceCardiac implantable electronic device-related complicationsCardiac implantable electronic device-related infectionsCardiac sarcoidosisImplantable cardioverter-defibrillator in cardiac sarcoidosis

Autor:innen und Institutionen

  • Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Region Väst…
  • Department of Cardiology, Clinical Sciences, Lund University, Lund, Sweden; Department of Cardiology, Skåne University Hospital, Lund and Malmö, Sweden.
  • Danderyd Hospital, Region Stockholm, Sweden.
  • Department of Cardiology, Clinical Sciences, Lund University, Lund, Sweden.
  • Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Re…
  • Department of Cardiology, Södra Älvsborg Hospital, Region Västra Götaland, Sweden.

Förderung

  • The Swedish Heart Lung Foundation
  • Skåne University Hospital Lund

Zitieren

APA

Taha, A., Slättman, A., Bobbio, E., Hamidi, K., Martinsson, A., Chaudhry, U., Demidova, M. M., Mokhtari, A., Polte, C. L., Szamlewski, P., Bollano, E., & Platonov, P. G. (2026). Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.07.014

Vancouver

Taha A, Slättman A, Bobbio E, Hamidi K, Martinsson A, Chaudhry U, et al. Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.07.014

BibTeX
@article{Taha2026,
  author = {Taha, Amar and Slättman, Anna and Bobbio, Emanuele and Hamidi, Kamal and Martinsson, Andreas and Chaudhry, Uzma and Demidova, Marina M and Mokhtari, Arash and Polte, Christian L and Szamlewski, Piotr and Bollano, Entela and Platonov, Pyotr G},
  title = {Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden},
  journal = {Heart Rhythm},
  year = {2026},
  doi = {10.1016/j.hrthm.2026.07.014}
}
Kostenlos starten →