Transvenous cardiac implantable electronic devices withstand contact sports in an experimental model

Felix K Wegner iD, Mauritz Drewes, Moritz Martinovic iD, Matthias Klimek iD, Julian Wolfes iD, Fabienne Kreimer iD, Christian Ellermann iD, Florian Reinke, Gerrit Frommeyer iD, Christoph Kittl iD, Lars Eckardt iD

Europace · 01.09.2025 · 27 (9)

DOI: 10.1093/europace/euaf191 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 22.08.2025. Verfasst von Felix K Wegner und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology II - Electrophysiology, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149 Muenster, Germany. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial, Rib Fractures, Cardiac Resynchronization Therapy Devices. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Cardiac implantable electronic device (CIED) patients are routinely advised against physical activity with a risk of collision because of expected damage to the implanted device. However, no data support this practice. Methods and results Sixteen CIED systems (six pacemakers, six ICD, four CRT-D) from all manufacturers were implanted subcutaneously in a porcine thorax and increasing weights were dropped on the experimental setting. Cardiac implantable electronic device function was analysed in an interactive heart simulator (InterSim III, IB Lang). In a second experiment, forces resulting in irreversible damage were investigated in explanted CIED. No signs of malfunction were seen in any CIED after a total of 256 impacts up to 2000 N. Forces exceeding 1500 N reproducibly led to rib fractures of the porcine thorax, in line with previous reports describing serial rib fractures in humans at similar forces. One IS1/DF1 single-coil implantable cardioverter/defibrillator (ICD) lead was bent after an impact of 900 N; however, no signs of lead malfunction were noted on inspection and fluoroscopy. When testing explanted CIED to failure, only 4 of 16 CIEDs (25%) showed signs of damage on fluoroscopy. Two ICDs were unable to terminate VF despite reporting normal shock impedances before VF induction.

Conclusion

This is the first study to analyse the effects of blunt force trauma on CIED. Our data suggest that CIED systems withstand contact sports impacts, which can result in serial rib fractures in humans. Therefore, general traumatological risks could outweigh the risks of CIED damage in sports with a low risk of collision. If damage is suspected, device interrogation should be performed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialRib FracturesCardiac Resynchronization Therapy DevicesSportsAnimalsSwineEquipment Failure AnalysisHumansStress, MechanicalProsthesis FailureModels, AnimalProsthesis Design

Stichwörter der Autor:innen

Blunt forceDefibrillatorICDPacemakerSports

Autor:innen und Institutionen

  • Department of Cardiology II - Electrophysiology, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149 Muenster, Germany.
  • Department of Trauma, Hand and Reconstructive Surgery, University Hospital Muenster, 48149 Muenster, Germany.

ORCID-Profile: Felix K Wegner, Moritz Martinovic, Matthias Klimek, Julian Wolfes, Fabienne Kreimer, Christian Ellermann, Gerrit Frommeyer, Christoph Kittl, Lars Eckardt

Zitieren

APA

Wegner, F. K., Drewes, M., Martinovic, M., Klimek, M., Wolfes, J., Kreimer, F., Ellermann, C., Reinke, F., Frommeyer, G., Kittl, C., & Eckardt, L. (2025). Transvenous cardiac implantable electronic devices withstand contact sports in an experimental model. Europace, 27(9). https://doi.org/10.1093/europace/euaf191

Vancouver

Wegner FK, Drewes M, Martinovic M, Klimek M, Wolfes J, Kreimer F, et al. Transvenous cardiac implantable electronic devices withstand contact sports in an experimental model. Europace. 2025;27(9). doi:10.1093/europace/euaf191

BibTeX
@article{Wegner2025,
  author = {Wegner, Felix K and Drewes, Mauritz and Martinovic, Moritz and Klimek, Matthias and Wolfes, Julian and Kreimer, Fabienne and Ellermann, Christian and Reinke, Florian and Frommeyer, Gerrit and Kittl, Christoph and Eckardt, Lars},
  title = {Transvenous cardiac implantable electronic devices withstand contact sports in an experimental model},
  journal = {Europace},
  year = {2025},
  volume = {27},
  number = {9},
  doi = {10.1093/europace/euaf191}
}
Kostenlos starten →