Catheter-based pulmonary vein isolation fails to prevent transient atrial arrhythmogenic changes related to acute obstructive respiratory events in a porcine model
Europace · 03.06.2024 · 26 (6)
DOI: 10.1093/europace/euae132 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 17.05.2024. Verfasst von Julie Norup Hertel und 15 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health and Medical Sciences, Department of Biomedical Sciences, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Disease Models, Animal, Catheter Ablation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NNF Young Investigator Awards 2021, Independent Research Fund Denmark, NNF Tandem Programme.
Abstract (Originalsprache)
Aims
Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. Methods and results In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: −57 ± 34 ms, P = 0.0002; in the LA: −42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)].
Conclusion
Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Health and Medical Sciences, Department of Biomedical Sciences, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.
- West German Heart and Vascular Center, Institute of Pharmacology, University Duisburg-Essen, Germany.
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands.
- Department of Cardiology, Zealand University Hospital Roskilde, Roskilde, Denmark.
- Division of Cardiology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.
- Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, Royal Adelaide Hospital, University of Adelaide, Australia.
ORCID-Profile: Jonas L Isaksen, Kezia Jerltorp, Sarah Dalgas Nissen, Arnela Saljic, Benedikt Linz, Stefan Sattler, Jakob Overgaard Larsen, Malene Nørregaard, Sevasti-Maria Chaldoupi, Uffe Gang, Martin Manninger, Thomas Jespersen, Dominik Linz
Förderung
- NNF Young Investigator Awards 2021
- Independent Research Fund Denmark
- NNF Tandem Programme
Zitieren
APA
Norup Hertel, J., Isaksen, J. L., Jerltorp, K., Dalgas Nissen, S., Hansen, M., Saljic, A., Linz, B., Sattler, S., Ye, C., Overgaard Larsen, J., Nørregaard, M., Chaldoupi, S. M., Gang, U., Manninger, M., Jespersen, T., & Linz, D. (2024). Catheter-based pulmonary vein isolation fails to prevent transient atrial arrhythmogenic changes related to acute obstructive respiratory events in a porcine model. Europace, 26(6). https://doi.org/10.1093/europace/euae132
Vancouver
Norup Hertel J, Isaksen JL, Jerltorp K, Dalgas Nissen S, Hansen M, Saljic A, et al. Catheter-based pulmonary vein isolation fails to prevent transient atrial arrhythmogenic changes related to acute obstructive respiratory events in a porcine model. Europace. 2024;26(6). doi:10.1093/europace/euae132
BibTeX
@article{NorupHertel2024,
author = {Norup Hertel, Julie and Isaksen, Jonas L and Jerltorp, Kezia and Dalgas Nissen, Sarah and Hansen, Malthe and Saljic, Arnela and Linz, Benedikt and Sattler, Stefan and Ye, Charles and Overgaard Larsen, Jakob and Nørregaard, Malene and Chaldoupi, Sevasti-Maria and Gang, Uffe and Manninger, Martin and Jespersen, Thomas and Linz, Dominik},
title = {Catheter-based pulmonary vein isolation fails to prevent transient atrial arrhythmogenic changes related to acute obstructive respiratory events in a porcine model},
journal = {Europace},
year = {2024},
volume = {26},
number = {6},
doi = {10.1093/europace/euae132}
}
EUVIMED