Septal venous channel perforation during left bundle branch area pacing: a prospective study
Europace · 2024
DOI: 10.1093/europace/euae124 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2024. Verfasst von Anindya Ghosh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, 4-A, Dr. JJ Nagar, Mogappair, Chenn…. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). Methods and results All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I–VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5–74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50–75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation—median θ (IQR) [19 (10–30)° vs. 5 (4–19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10–14.8) vs. 10 (8.5–12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different.
Conclusion
When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, 4-A, Dr. JJ Nagar, Mogappair, Chennai, Tamil Nadu 600037, India.
- Division of Cardiology, Sub-section of Electrophysiology, Children's Hospital of Michigan and Detroit Medical Center, Detroit, MI, USA.
- Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, The Madras Medical Mission, Chennai, Tamil Nadu, India.
- Center for Arrhythmia Care, Section of Cardiology, University of Chicago Pritzker School of Medicine, Chicago, IL, USA.
ORCID-Profile: Anindya Ghosh, Anbarasan Sekar, Chenni S Sriram, Kothandam Sivakumar, Gaurav A Upadhyay
Zitieren
APA
Ghosh, A., Sekar, A., Sriram, C. S., Sivakumar, K., Upadhyay, G. A., & Pandurangi, U. M. (2024). Septal venous channel perforation during left bundle branch area pacing: a prospective study. Europace. https://doi.org/10.1093/europace/euae124
Vancouver
Ghosh A, Sekar A, Sriram CS, Sivakumar K, Upadhyay GA, Pandurangi UM. Septal venous channel perforation during left bundle branch area pacing: a prospective study. Europace. 2024. doi:10.1093/europace/euae124
BibTeX
@article{Ghosh2024,
author = {Ghosh, Anindya and Sekar, Anbarasan and Sriram, Chenni S and Sivakumar, Kothandam and Upadhyay, Gaurav A and Pandurangi, Ulhas M},
title = {Septal venous channel perforation during left bundle branch area pacing: a prospective study},
journal = {Europace},
year = {2024},
doi = {10.1093/europace/euae124}
}
EUVIMED