Kurz gefasst

Metaanalyse in der Zeitschrift Europace, 2023. Verfasst von Zaki Akhtar und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St George's University Hospital, London, UK. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 90 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Abbott Medical..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. Methods and results We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77–2.63), P < 0.01] and complete [OR 1.87 (1.69–2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02–2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01).

Conclusion

Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialHumansVena Cava, SuperiorDevice RemovalLasersCardiac CatheterizationTreatment OutcomeRetrospective Studies

Stichwörter der Autor:innen

Laser lead extractionLead extractionNon-laser lead extractionRotational lead extractionTransvenous lead extraction

Autor:innen und Institutionen

  • Department of Cardiology, St George's University Hospital, London, UK.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • Department of Clinical Therapeutics, National and Kapodistrian University of Athens, Athens, Greece.
  • Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.
  • Department of Medicine, San Joaquin General Hospital, French Camp, CA, USA.
  • Division of Cardiology, University of California, San Francisco, CA, USA.

ORCID-Profile: Zaki Akhtar, Christos Kontogiannis, Christoph T Starck, Lisa W M Leung, Sun Y Lee, Byron K Lee, Sreenivasa R K Seshasai, Mark M Gallagher

Förderung

  • Abbott Medical.

Zitieren

APA

Akhtar, Z., Kontogiannis, C., Georgiopoulos, G., Starck, C. T., Leung, L. W. M., Lee, S. Y., Lee, B. K., Seshasai, S. R. K., Sohal, M., & Gallagher, M. M. (2023). Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Europace. https://doi.org/10.1093/europace/euad316

Vancouver

Akhtar Z, Kontogiannis C, Georgiopoulos G, Starck CT, Leung LWM, Lee SY, et al. Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Europace. 2023. doi:10.1093/europace/euad316

BibTeX
@article{Akhtar2023,
  author = {Akhtar, Zaki and Kontogiannis, Christos and Georgiopoulos, Georgios and Starck, Christoph T and Leung, Lisa W M and Lee, Sun Y and Lee, Byron K and Seshasai, Sreenivasa R K and Sohal, Manav and Gallagher, Mark M},
  title = {Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis},
  journal = {Europace},
  year = {2023},
  doi = {10.1093/europace/euad316}
}
Kostenlos starten →