Octogenarian patients and laser-assisted lead extraction: Should we put a limit?

Sameer Al-Maisary iD, Gabriele Romano, Matthias Karck, Raffaele De Simone, Jamila Kremer, Rawa Arif

PLOS ONE · 20.10.2023 · 18 (10) · e0284802

DOI: 10.1371/journal.pone.0284802 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 20.10.2023. Verfasst von Sameer Al-Maisary und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Atrial Fibrillation, Pacemaker, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transvenous laser lead extraction (TLE) for cardiac implantable electric devices (CIED) is a challenging procedure especially if performed in octogenarians. In this study we evaluated the safety and efficacy of transvenous laser lead extraction in elderly patients.

Methods

This is a retrospective study of octogenarian patients who underwent laser-assisted lead extraction (LLE) (GlideLight laser sheath, Philips, San Diego, USA). 270 Consecutive patients were included. Patients were divided into two groups. Octogenarian group and non-octogenarian group. The Data was gathered from patients treated between September 2013 and January 2020 and is retrospectively analyzed.

Results

Of 270 consecutive patients, 38 (14.0%) were 80 years old or more. The total number of the extracted leads was 556 among which 84(15.0%) from the Octogenarian group. From these leads were 155 single coil leads, 82 dual coil leads, 129 right ventricular pacing leads, 155 right atrial leads, and 35 left ventricular leads. In the Octogenarian group the number of removed leads was as follows: 13 single coil leads, 10 dual coil leads, 28 right ventricular pacing leads, 28 right atrial leads and 5 left ventricular leads. No mortality was recorded in the Octogenarian group. One patient in the YG suffered from a superior vena cava tear and one patient suffered from pulmonary embolism.

Conclusion

In octogenarian laser assisted lead extraction patients is a safe and effective procedure. No increase in morbidity, mortality or perioperative complication could be recorded in this group. Age should not be a limiting factor to perform this procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableAtrial FibrillationPacemaker, ArtificialAged, 80 and overHumansAgedRetrospective StudiesOctogenariansVena Cava, SuperiorLasersDevice RemovalTreatment Outcome

Autor:innen und Institutionen

  • Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.

ORCID-Profile: Sameer Al-Maisary

Zitieren

APA

Al-Maisary, S., Romano, G., Karck, M., De Simone, R., Kremer, J., & Arif, R. (2023). Octogenarian patients and laser-assisted lead extraction: Should we put a limit?. PLOS ONE, 18(10), e0284802. https://doi.org/10.1371/journal.pone.0284802

Vancouver

Al-Maisary S, Romano G, Karck M, De Simone R, Kremer J, Arif R. Octogenarian patients and laser-assisted lead extraction: Should we put a limit?. PLOS ONE. 2023;18(10):e0284802. doi:10.1371/journal.pone.0284802

BibTeX
@article{AlMaisary2023,
  author = {Al-Maisary, Sameer and Romano, Gabriele and Karck, Matthias and De Simone, Raffaele and Kremer, Jamila and Arif, Rawa},
  title = {Octogenarian patients and laser-assisted lead extraction: Should we put a limit?},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {10},
  pages = {e0284802},
  doi = {10.1371/journal.pone.0284802}
}
Kostenlos starten →