Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation
Europace · 02.08.2023 · 25 (9)
DOI: 10.1093/europace/euad269 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 15.09.2023. Verfasst von Majd Al Deen Alhuarrat und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Internal Medicine, Jacobi Medical Center, Albert Einstein College Medicine, Bronx, NY, USA. Hauptthemen laut MEDLINE: Arrhythmias, Cardiac, Pacemaker, Artificial. Die Arbeit wurde bisher 38-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: commercial.
Abstract (Originalsprache)
Aims
Since their introduction in 1958, traditional cardiac pacemakers have undergone considerable upgrades over the years, but they continue to have a complication rate of ∼3.8%–12.4%. There are no randomized controlled trials comparing outcomes of leadless pacemakers (LPM) with single-chamber transvenous pacemakers (TV-VVI). The aim is to assess the differences in the procedural complications and in-hospital outcomes between LPM and TV-VVI implants. Methods and results We queried the national inpatient database from 2016 to 2019 to include adult patients undergoing LPM and TV-VVI. Admissions for leadless and single-lead transvenous pacemakers were identified by their appropriate ICD-10 codes. Complications were identified using ICD-10 codes that mostly represent initial encounter. The difference in outcomes was assessed using multivariable logistic regression and 1:1 propensity score matching between the two cohorts. Thirty-five thousand four hundred thirty expanded samples of admissions were retrieved of which 27 650 (78%) underwent TV-VVI with a mean age 81.3 ± 9.4 years and 7780 (22%) underwent LPM with a mean age of 77.1 ± 12.1 years. The LPM group had a higher likelihood of in-hospital mortality [adjusted odds ratio (aOR): 1.63, 95% CI (1.29–2.05), P < 0.001], vascular complications [aOR: 7.54, 95% CI (3.21–17.68), P < 0.001], venous thromboembolism [aOR: 3.67, 95% CI (2.68–5.02), P < 0.001], cardiac complications [aOR: 1.79, 95% CI (1.59–2.03), P < 0.001], device thrombus formation [aOR: 5.03, 95% CI (2.55–9.92), P < 0.001], and need for a blood transfusion [aOR: 1.54, 95% CI (1.14–2.07), P < 0.005]. The TV-VVI group had higher likelihood of in-hospital pulmonary complications [aOR:0.68, 95% CI (0.54–0.87), P < 0.002] and had a need for device revisions [aOR:0.42, 95% CI (0.23–0.76), P < 0.004].
Conclusion
There is a higher likelihood of all-cause in-hospital mortality and complications following LPM implantation in comparison to TV-VVI. This could be related to higher co-morbidities in the LPM group. Clinical trials aimed to accurately compare these two groups should be undertaken.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Internal Medicine, Jacobi Medical Center, Albert Einstein College Medicine, Bronx, NY, USA.
- Department of Internal Medicine, Rochester Regional Health/Unity Hospital, Rochester, NY, USA.
- Department of Cardiology, Rochester Regional Health, Rochester, NY, USA.
- Division of Cardiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 East 210th Street, Bronx, NY 10467, USA.
ORCID-Profile: Majd Al Deen Alhuarrat, Amrin Kharawala, Sarath Renjithlal, Mohamed Magdi Eid, Dimitrios Varrias, Moghniuddin Mohammed, Luigi Di Biase
Förderung
- commercial
Zitieren
APA
Alhuarrat, M. A. D., Kharawala, A., Renjithlal, S., Magdi Eid, M., Varrias, D., Mohammed, M., Grushko, M., & Di Biase, L. (2023). Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation. Europace, 25(9). https://doi.org/10.1093/europace/euad269
Vancouver
Alhuarrat MAD, Kharawala A, Renjithlal S, Magdi Eid M, Varrias D, Mohammed M, et al. Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation. Europace. 2023;25(9). doi:10.1093/europace/euad269
BibTeX
@article{Alhuarrat2023,
author = {Alhuarrat, Majd Al Deen and Kharawala, Amrin and Renjithlal, Sarath and Magdi Eid, Mohamed and Varrias, Dimitrios and Mohammed, Moghniuddin and Grushko, Michael and Di Biase, Luigi},
title = {Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation},