EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing

Toshiaki Sato iD, Ikuko Togashi iD, Hirotsugu Ikewaki iD, Takato Mohri iD, Yumi Katsume iD, Mika Tashiro, Noriko Nonoguchi iD, Kyoko Hoshida, Akiko Ueda iD, Seiichiro Matsuo, Kyoko Soejima

Europace · 02.08.2023 · 25 (9)

DOI: 10.1093/europace/euad241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 25.09.2023. Verfasst von Toshiaki Sato und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Advanced Arrhythmia Management, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo 181-8611, Japan. Hauptthemen laut MEDLINE: Atrioventricular Block, Ventricular Septum. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. Methods and results Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex.

Conclusion

Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrioventricular BlockVentricular SeptumHumansHeart Conduction SystemHeart VentriclesCardiac Conduction System Disease

Stichwörter der Autor:innen

Atrioventricular blockLeft bundle branch area pacingLeft bundle branch pacingLeft fascicular pacingLeft ventricular septal pacing

Autor:innen und Institutionen

  • Division of Advanced Arrhythmia Management, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo 181-8611, Japan.
  • Department of Cardiovascular Medicine, Kyorin University School of Medicine, Mitaka, Japan.

ORCID-Profile: Toshiaki Sato, Ikuko Togashi, Hirotsugu Ikewaki, Takato Mohri, Yumi Katsume, Noriko Nonoguchi, Akiko Ueda

Zitieren

APA

Sato, T., Togashi, I., Ikewaki, H., Mohri, T., Katsume, Y., Tashiro, M., Nonoguchi, N., Hoshida, K., Ueda, A., Matsuo, S., & Soejima, K. (2023). Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing. Europace, 25(9). https://doi.org/10.1093/europace/euad241

Vancouver

Sato T, Togashi I, Ikewaki H, Mohri T, Katsume Y, Tashiro M, et al. Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing. Europace. 2023;25(9). doi:10.1093/europace/euad241

BibTeX
@article{Sato2023,
  author = {Sato, Toshiaki and Togashi, Ikuko and Ikewaki, Hirotsugu and Mohri, Takato and Katsume, Yumi and Tashiro, Mika and Nonoguchi, Noriko and Hoshida, Kyoko and Ueda, Akiko and Matsuo, Seiichiro and Soejima, Kyoko},
  title = {Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing},
  journal = {Europace},
  year = {2023},
  volume = {25},
  number = {9},
  doi = {10.1093/europace/euad241}
}
Kostenlos starten →