Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial
European Journal of Orthodontics · 2024
DOI: 10.1093/ejo/cjad079 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift European Journal of Orthodontics, 2024. Verfasst von Giau Tran und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Saint Louis University, Saint Louis, MO 63104, USA. Hauptthemen laut MEDLINE: Stainless Steel, Orthodontic Appliance Design. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
Retention has been always considered a major challenge in orthodontics. Recently computer-aided design/computer-aided manufacturing (CAD/CAM) fixed retainers (FRs) have been introduced as a marked development in retainer technology, offering potential advantages.
Objective
The objective of this study was to compare the differences in relapse and failure rates in patients treated with FRs using CAD/CAM technology, lab-based technique, and chairside method. Trial design A double-blinded, prospective, randomized controlled clinical trial was conducted over a 2-year period at a single centre.
Methods
Participants Initially, 81 patients were recruited, but only 43 patients who came back for a 2-year retention were included in the study.
Interventions
These patients were divided into three groups: CAD/CAM group with multistranded Stainless Steel wires (CAD/CAM, n = 14), lab group with the same multistranded wires (lab, n = 15), and a chairside group with Stainless Steel Ortho-FlexTech wires (chairside, n = 14). Outcomes Inter-canine width (ICW) and Little’s irregularity index were digitally measured from scans at the orthodontic debonding (T1), 6-month retention (T2), 1-year retention (T3), and 2-year retention (T4) visits. All forms of failure were documented and analyzed. Randomization Participants were randomly assigned to the three groups using online randomization software (randomization.com) by a statistician who was not involved in the study. Blinding Patients were blinded in terms of the FR group to which they were each randomly assigned. The principal investigator was blinded upon data analysis since patients’ records were coded to minimize observer and measurement bias.
Results
Initially 81 patients were assessed for eligibility. Seventy-five patients were randomly allocated into the three study groups. After 2-year follow-up, 43 patients came back for the follow-up and were analyzed. The CAD/CAM group showed significantly less reduction in ICW compared to the chairside group at all time intervals (P < .05) and compared to the lab group at 6 months (P = .038). In terms of LII, the CAD/CAM group exhibited significantly less change than the chairside and lab groups at all time intervals (P < .05). The CAD/CAM group had the lowest failure rate (21.4%), followed by chairside group (28.6%) and then lab group (33.3%), however the differences were insignificant. No harms were observed in the current study.
Conclusion
Within 2 years of fixed retention, CAD/CAM FRs showed significantly less relapse than lab-based and chairside FRs. However, there was no significant difference in failure rates among the groups.
Trial registration
NCT05915273
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthodontics, Saint Louis University, Saint Louis, MO 63104, USA.
- Department of Orthodontics, Faculty of Dentistry, Alexandria University, Alexandria 21526, Egypt.
ORCID-Profile: Samar M Adel
Zitieren
APA
Tran, G., Rucker, R., Foley, P., Bankhead, B., Adel, S. M., & Kim, K. B. (2024). Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial. European Journal of Orthodontics. https://doi.org/10.1093/ejo/cjad079
Vancouver
Tran G, Rucker R, Foley P, Bankhead B, Adel SM, Kim KB. Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial. European Journal of Orthodontics. 2024. doi:10.1093/ejo/cjad079
BibTeX
@article{Tran2024,
author = {Tran, Giau and Rucker, Ryan and Foley, Patrick and Bankhead, Brent and Adel, Samar M and Kim, Ki Beom},
title = {Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial},
journal = {European Journal of Orthodontics},
year = {2024},
doi = {10.1093/ejo/cjad079}
}
EUVIMED