The prevalence of the failure of fixed orthodontic bonded retainers: a systematic review and meta-analysis
European Journal of Orthodontics · 2023
DOI: 10.1093/ejo/cjad047 ↗Kurz gefasst
Metaanalyse in der Zeitschrift European Journal of Orthodontics, 2023. Verfasst von Su Thae Aye und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Dentistry, Faculty of Biology, Medicine and Health, University of Manchester, UK. Hauptthemen laut MEDLINE: Orthodontic Appliances, Fixed, Orthodontic Retainers. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: University of Manchester.
Abstract (Originalsprache)
Objectives
To systematically assess the scientific literature for the prevalence of failure rate of fixed orthodontic bonded retainer (FOBR).
Method
Randomized clinical trials (RCTs) and prospective non-RCTs involving participants who had FOBR fitted were included. The Cochrane Central Register of Controlled Trials, Web of science, MEDLINE, and EMBASE via OVID were searched from inception to January 2023. Risk of bias was assessed using the Cochrane RoB 2 and Newcastle–Ottawa tools. The main outcome was the failure rate of FOBRs. The secondary outcome was to identify factors that can influence the failure of FOBR. Meta-analyses and sensitivity analyses were undertaken using Revman, version5.4. A random-effects model was used. Quality assessment using Grading of Recommendations Assessment, Development, and Evaluation.
Results
Thirty-four studies (25 RCTs and 9 prospective clinical studies) (3484 participants) were included in this review. The overall failure rate of bonded retainers, after excluding high-risk studies, was 35.22% (95% confidence interval [CI] 27.46–42.98). The failure rate is increased with the duration of follow up; with short-term follow-up rate 24.18% (95% CI 20.16–28.21), medium-term follow up 40.09% (95% CI 30.92–49.26), and long-term follow up 53.85% (95% CI 40.31–67.39). There is a low level of evidence to suggest there is no statistically significant difference in the failure rate of fixed retainers using direct versus indirect bonding methods, using liquid resin versus without liquid resin, and fibre-reinforced composite retainers compared to multi-stranded stainless steel retainers.
Discussion
There is low-quality evidence to suggest that the failure rate of FOBR is relatively high. There is a need for high-quality, well-reported clinical studies to assess factors that can influence the failure rate of FOBR. Registration CRD42021190910.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Dentistry, Faculty of Biology, Medicine and Health, University of Manchester, UK.
- University Dental Hospital of Manchester, MFT NHS Trust, UK.
Förderung
- University of Manchester
Zitieren
APA
Aye, S. T., Liu, S., Byrne, E., & El-Angbawi, A. (2023). The prevalence of the failure of fixed orthodontic bonded retainers: a systematic review and meta-analysis. European Journal of Orthodontics. https://doi.org/10.1093/ejo/cjad047
Vancouver
Aye ST, Liu S, Byrne E, El-Angbawi A. The prevalence of the failure of fixed orthodontic bonded retainers: a systematic review and meta-analysis. European Journal of Orthodontics. 2023. doi:10.1093/ejo/cjad047
BibTeX
@article{Aye2023,
author = {Aye, Su Thae and Liu, Shiyao and Byrne, Emer and El-Angbawi, Ahmed},
title = {The prevalence of the failure of fixed orthodontic bonded retainers: a systematic review and meta-analysis},
journal = {European Journal of Orthodontics},
year = {2023},
doi = {10.1093/ejo/cjad047}
}
EUVIMED