Post-implant transcatheter aortic prosthesis deformation: tricuspid versus bicuspid valve
European Journal of Cardio-Thoracic Surgery · 26.12.2024 · 67 (1)
DOI: 10.1093/ejcts/ezae451 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 13.12.2024. Verfasst von Marco Moscarelli und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care&Research, Palermo, Italy. Hauptthemen laut MEDLINE: Aortic Valve, Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: European.
Abstract (Originalsprache)
OBJECTIVES We sought to assess whether post-implant transcatheter aortic valve prosthesis multidetector computed characteristics differ between patients with native tricuspid and bicuspid aortic valve stenosis, as well as the effect on valve performance and clinical implications. METHODS We analysed 100 consecutive post-implant multidetector computed tomography scans to assess self-expandable prosthesis non-uniform expansion at 6 pre-specified valvular levels, and other specific parameters, including valvular and perivalvular thrombosis at 6 months follow-up. Echocardiographic prosthesis performance and clinical outcome were also evaluated. RESULTS Mean eccentricity was significantly higher in the bicuspid group (0.43 (0.09) vs 0.37 (0.08), P = 0.005, bicuspid vs tricuspid); valvular and perivalvular thrombosis were also significantly more frequent in the bicuspid than in the tricuspid group (81% vs 36.9%, P = 0.031); there was no significant difference in terms of mean prosthetic gradient at follow-up between (7.31 (5.53 mmHg) vs 7.09 (3.05 mmHg), P = 0.825); EOAi (indexed effective orifice area) was also similar between bicuspid and tricuspid (1.08 (0.12 cm2) vs 1.03 (0.13 cm2), P = 0.101), with no significant changes compared to discharge. However, the bicuspid valve was associated with a significantly higher risk of adverse events (HR: 3.72, 95% CI: 1.07–13.4, P = 0.027). CONCLUSIONS Higher level of eccentricity, which indicates prosthesis deformation, is often detected in bicuspid valves. Although echocardiographic performance was not affected, this might have led to an increased incidence of thrombosis at valvular and perivalvular levels and worse outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care&Research, Palermo, Italy.
- Surgery and Cancer, Imperial College, London, UK.
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
- College of Medicine, The Ohio State University, Columbus, Ohio, USA.
- Department of Radiology, Maria Eleonora Hospital, GVM Care&Research, Palermo, Italy.
- Department of Measurement and Electronics, AGH University of Science and Technology, Krakow, Poland.
ORCID-Profile: Marco Moscarelli, Khalil Fattouch
Förderung
- European
Zitieren
APA
Moscarelli, M., Venkatesh, A., Berland, K., Yeats, B., Becker, T., Zaccone, G., Pernice, V., Milo, S., Zlahoda-Huzior, A., Dudek, D., Trizzino, F., Speziale, G., Dasi, L. P., & Fattouch, K. (2024). Post-implant transcatheter aortic prosthesis deformation: tricuspid versus bicuspid valve. European Journal of Cardio-Thoracic Surgery, 67(1). https://doi.org/10.1093/ejcts/ezae451
Vancouver
Moscarelli M, Venkatesh A, Berland K, Yeats B, Becker T, Zaccone G, et al. Post-implant transcatheter aortic prosthesis deformation: tricuspid versus bicuspid valve. European Journal of Cardio-Thoracic Surgery. 2024;67(1). doi:10.1093/ejcts/ezae451
BibTeX
@article{Moscarelli2024,
author = {Moscarelli, Marco and Venkatesh, Aniket and Berland, Katelynne and Yeats, Breandan and Becker, Taylor and Zaccone, Gregorio and Pernice, Vincenzo and Milo, Sabrina and Zlahoda-Huzior, Adriana and Dudek, Dariusz and Trizzino, Francesca and Speziale, Giuseppe and Dasi, Lakshmi Prasad and Fattouch, Khalil},
title = {Post-implant transcatheter aortic prosthesis deformation: tricuspid versus bicuspid valve},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2024},
volume = {67},
number = {1},
doi = {10.1093/ejcts/ezae451}
}
EUVIMED