Flaring of Protruding Coronary Stents Before Transcatheter Aortic Valve Replacement to Minimize Interaction—A Feasibility Study
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31378 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Jonathan X Fang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Center for Structural Heart Disease, Henry Ford Health System, Detroit, Michigan, USA. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Stents, Aortic Valve Stenosis, Aortic Valve. Die Arbeit nennt 11 Literaturangaben.
Abstract (Originalsprache)
Background
Protruding coronary artery stents can adversely affect transcatheter aortic valve replacement (TAVR) procedure. Current evidence on the topic is limited.
Aims
We aim to study the clinical feasibility and safety of flaring of protruding coronary artery stents before TAVR to reduce interaction with transcatheter heart valves.
Methods
Twenty consecutive patients with 22 protruding coronary stents were optimized with a dual‐diameter balloon before TAVR. Procedural success, stent and valve geometry on angiogram, periprocedural and subsequent clinical outcomes as well as valve hemodynamics on echocardiography were evaluated.
Results
Procedural success was achieved in 100% of coronary procedure and TAVR without any major complication directly related to the flaring of stents. There was no coronary artery obstruction after TAVR or visible stent or valve deformity. All valves had normal hemodynamics immediately post‐deployment with none having clinically significant aortic insufficiency. One patient had inpatient mortality unrelated to coronary stent optimization. One valve had hemodynamic valve degeneration on follow‐up which was unrelated to coronary stent flaring and the patient was asymptomatic.
Conclusion
Flaring of protruding coronary stents before TAVR is technically feasible and safe and can potentially minimize stent‐valve interaction during or after TAVR. [Correction added on 9th July 2025, after first online publication: This sentence was updated to correct typos.]
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Center for Structural Heart Disease, Henry Ford Health System, Detroit, Michigan, USA.
- College of Medicine and Life Sciences, University of Toledo, Toledo, Ohio, USA.
- Cardiac Imaging, NCH Rooney Heart Institute, Naples, Florida, USA.
Zitieren
APA
Fang, J. X., Engel Gonzalez, P., Villablanca, P. A., Frisoli, T. M., Kamel-Abusalha, L. B., Lee, J. C., Giustino, G., Wang, D. D., O'Neill, W. W., & O'Neill, B. P. (2025). Flaring of Protruding Coronary Stents Before Transcatheter Aortic Valve Replacement to Minimize Interaction—A Feasibility Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31378
Vancouver
Fang JX, Engel Gonzalez P, Villablanca PA, Frisoli TM, Kamel-Abusalha LB, Lee JC, et al. Flaring of Protruding Coronary Stents Before Transcatheter Aortic Valve Replacement to Minimize Interaction—A Feasibility Study. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31378
BibTeX
@article{Fang2025,
author = {Fang, Jonathan X and Engel Gonzalez, Pedro and Villablanca, Pedro A and Frisoli, Tiberio M and Kamel-Abusalha, Louie B and Lee, James C and Giustino, Gennaro and Wang, Dee Dee and O'Neill, William W and O'Neill, Brian P},
title = {Flaring of Protruding Coronary Stents Before Transcatheter Aortic Valve Replacement to Minimize Interaction—A Feasibility Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31378}
}
EUVIMED