Twenty-five years’ experience with isolated bicuspid aortic valve repair: impact of commissural orientation
European Journal of Cardio-Thoracic Surgery · 2024
DOI: 10.1093/ejcts/ezae163 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2024. Verfasst von Tristan Ehrlich und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg, Germany. Hauptthemen laut MEDLINE: Bicuspid Aortic Valve Disease, Aortic Valve, Aortic Valve Insufficiency. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg, Germany.
- Department of Cardiovascular Surgery and Heart Transplantation, University Hospital of Nancy-Brabois, Vandoeuvre-lès-Nancy, France.
ORCID-Profile: Tristan Ehrlich, Karen B Abeln, Christian Giebels, Hans-Joachim Schäfers
Zitieren
APA
Ehrlich, T., Abeln, K. B., Froede, L., Schmitt, F., Giebels, C., & Schäfers, H. J. (2024). Twenty-five years’ experience with isolated bicuspid aortic valve repair: impact of commissural orientation. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezae163
Vancouver
Ehrlich T, Abeln KB, Froede L, Schmitt F, Giebels C, Schäfers HJ. Twenty-five years’ experience with isolated bicuspid aortic valve repair: impact of commissural orientation. European Journal of Cardio-Thoracic Surgery. 2024. doi:10.1093/ejcts/ezae163
BibTeX
@article{Ehrlich2024,
author = {Ehrlich, Tristan and Abeln, Karen B and Froede, Lennart and Schmitt, Flora and Giebels, Christian and Schäfers, Hans-Joachim},
title = {Twenty-five years’ experience with isolated bicuspid aortic valve repair: impact of commissural orientation},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2024},
doi = {10.1093/ejcts/ezae163}
}
EUVIMED