EUVIMEDEUVIMED entdecken
Crossref

Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation

Lan-Anh Nguyen, Umit Gencer, Guillaume Goudot, Damian Craiem, Mariano E Casciaro, Charles Cheng, Emmanuel Messas, Elie Mousseaux, Gilles Soulat

Diagnostic and Interventional Imaging · 2024

DOI: 10.1016/j.diii.2024.09.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostic and Interventional Imaging, 2024. Verfasst von Lan-Anh Nguyen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Université Paris Cité, INSERM, PARCC, Paris 75015, France; Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 75015 Paris, Fra…. Hauptthemen laut MEDLINE: Aortic Valve Insufficiency, Aortic Valve, Bicuspid Aortic Valve Disease, Heart Valve Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to evaluate the performance of four-dimensional (4D) flow cardiac MRI in quantifying aortic flow in patients with bicuspid aortic valve (BAV). MATERIALS AND METHODS: Patients with BAV who underwent transthoracic echocardiography (TTE) and 4D flow cardiac MRI were prospectively included. Aortic flow was quantified using two-dimensional phase contrast velocimetry at the sinotubular junction and in the ascending aorta and using 4D flow in the regurgitant jet, in the left ventricular outflow tract, at the aortic annulus, the sinotubular junction, and the ascending aorta, with or without anatomical tracking. Flow quantification was compared with ventricular volumes, pulmonary flow using Pearson correlation test, bias and limits of agreement (LOA) using Bland Altman method, and with multiparametric transthoracic echocardiography quantification using weighted kappa test. RESULTS: Eighty-eight patients (63 men, 25 women) with a mean age of 50.5 ± 14.8 (standard deviation) years (age range: 20.8-78.3) were included. Changes in flow with or without tracking were modest (< 5 mL). The best correlation was obtained at the aortic annulus for forward volume (r = 0.84; LOA [-28.4; 25.3] mL) and at the regurgitant jet and sinotubular junction for regurgitant volume (r = 0.68; LOA [-27.8; 33.8] and r = 0.69; LOA [-28.6; 24.2] mL). A combined approach for regurgitant fraction and net volume calculations using forward volume measured at ANN and regurgitant volume at sinotubular junction performed better than each level taken separately (r = 0.90; LOA [-20.7; 10.0] mL and r = 0.48, LOA [-33.8; 33.4] %). The agreement between transthoracic echocardiography and 4D flow cardiac MRI for aortic regurgitation grading was poor (kappa, 0.13 to 0.42). CONCLUSION: In patients with BAV, aortic flow quantification by 4D flow cardiac MRI is the most accurate at the annulus for the forward volume, and at the sinotubular junction or directly in the jet for the regurgitant volume.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve InsufficiencyAortic ValveBicuspid Aortic Valve DiseaseHeart Valve DiseasesHumansFemaleMaleMiddle AgedAdultAgedYoung AdultProspective StudiesMagnetic Resonance ImagingAortaEchocardiography

Stichwörter der Autor:innen

4D flow cardiac MRIAortic valve insufficiencyBicuspid aortic valve diseaseCardiac magnetic resonance imaging

Autor:innen und Institutionen

  • Université Paris Cité, INSERM, PARCC, Paris 75015, France; Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 75015 Paris, France.
  • Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, CP 1078 Buenos Aires, Argentina.
  • Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 75015 Paris, France.
  • Université Paris Cité, INSERM, PARCC, Paris 75015, France; Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 75015 Paris, France. Electronic address: gilles.soulat@aphp.fr.

Zitieren

APA

Nguyen, L. A., Gencer, U., Goudot, G., Craiem, D., Casciaro, M. E., Cheng, C., Messas, E., Mousseaux, E., & Soulat, G. (2024). Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation. Diagnostic and Interventional Imaging. https://doi.org/10.1016/j.diii.2024.09.001

Vancouver

Nguyen LA, Gencer U, Goudot G, Craiem D, Casciaro ME, Cheng C, et al. Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation. Diagnostic and Interventional Imaging. 2024. doi:10.1016/j.diii.2024.09.001

BibTeX
@article{Nguyen2024,
  author = {Nguyen, Lan-Anh and Gencer, Umit and Goudot, Guillaume and Craiem, Damian and Casciaro, Mariano E and Cheng, Charles and Messas, Emmanuel and Mousseaux, Elie and Soulat, Gilles},
  title = {Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation},
  journal = {Diagnostic and Interventional Imaging},
  year = {2024},
  doi = {10.1016/j.diii.2024.09.001}
}
Kostenlos starten →