Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair
Interdisciplinary CardioVascular and Thoracic Surgery · 01.04.2026 · 41 (4)
DOI: 10.1093/icvts/ivag103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 10.04.2026. Verfasst von Kay Maeda und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, The Jikei University School of Medicine, Tokyo, 105-8461, Japan. Hauptthemen laut MEDLINE: Bicuspid Aortic Valve Disease, Hemodynamics, Aortic Valve Insufficiency, Aortic Valve. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Postoperative stenosis negatively affects durability after bicuspid aortic valve (BAV) valvuloplasty. This study was performed to evaluate the haemodynamic efficacy of sinus plication (SP) to avoid stenosis after asymmetrical BAV repair.
Methods
Between 2018 and 2023, 41 patients with BAV (33.3 ± 11.5 years, 40 males) with moderate-severe aortic regurgitation (AR) underwent aortic valve repair with (SP group, n = 14) or without (NSP group, n = 27) SP. SP was performed to reduce the circumference of the fused sinus and restore sinus contour symmetry. Preoperative and postoperative haemodynamic parameters were assessed at discharge and 1 year using transthoracic echocardiography.
Results
No deaths occurred within 1 year after surgery in either group. AR was well controlled and adequate left ventricular reverse remodelling was observed in both the groups up to 1 year postoperatively. At 1 year, lower transvalvular peak pressure gradient (PG) and maximum transvalvular flow velocity (Vmax) were observed in the SP group (peak PG: 17.7 ± 5.5 mmHg; % change −8.8% ± 1.1%, Vmax: 1.9 ± 0.31 m/s; % change −13.1% ± 2.1%) compared with the NSP group (peak PG: 24.7 ± 9.6 mmHg; +8.8% ± 1.3%, Vmax: 2.58 ± 0.62 m/s; +9.3% ± 2.5%), while there were no clear differences in % changes of peak PG or Vmax between the groups after adjustment for covariates.
Conclusions
In BAV repair, SP was potentially associated with lower peak PG and Vmax at 1 year. These findings suggest that SP may enhance haemodynamic stability in BAV repair.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.
- Department of Cardiovascular Surgery, Bellland General Hospital, Sakai, 599-8247, Japan.
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, 371-8511, Japan.
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, Saitama, 330-8503, Japan.
- Department of Cardiovascular Surgery, Kawasaki Medical School, Okayama, 701-0192, Japan.
- Department of Cardiovascular Surgery, National Hospital Organization Okayama Medical Center, Okayama, 701-1192, Japan.
ORCID-Profile: Kay Maeda, Tomonobu Abe, Takashi Kunihara
Zitieren
APA
Maeda, K., Ichihara, N., Baba, T., Abe, T., Yamaguchi, A., Une, D., Nakai, M., Matsuura, H., Fujii, T., & Kunihara, T. (2026). Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair. Interdisciplinary CardioVascular and Thoracic Surgery, 41(4). https://doi.org/10.1093/icvts/ivag103
Vancouver
Maeda K, Ichihara N, Baba T, Abe T, Yamaguchi A, Une D, et al. Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair. Interdisciplinary CardioVascular and Thoracic Surgery. 2026;41(4). doi:10.1093/icvts/ivag103
BibTeX
@article{Maeda2026,
author = {Maeda, Kay and Ichihara, Nao and Baba, Toshio and Abe, Tomonobu and Yamaguchi, Atsushi and Une, Dai and Nakai, Mikizou and Matsuura, Hiroshi and Fujii, Takeshiro and Kunihara, Takashi},
title = {Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
volume = {41},
number = {4},
doi = {10.1093/icvts/ivag103}
}
EUVIMED