Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant

Maria Fernanda Silva Andrade-Bortoletto iD, Thaísa Pinheiro Silva iD, Marcela Tarosso Réa iD, Renata Maira de Souza Leal iD, Débora Costa Ruiz iD, Deborah Queiroz Freitas iD

Dentomaxillofacial Radiology · 30.10.2026

DOI: 10.1093/dmfr/twag070 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, online erschienen am 30.10.2026. Verfasst von Maria Fernanda Silva Andrade-Bortoletto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the diagnostic accuracy of 3 cone beam computed tomography (CBCT) acquisition protocols, 1 low-resolution (LR) and 2 high-resolution (HR) protocols, using a metal artifact reduction tool (MAR) for detecting a second canal in mandibular incisors adjacent to a zirconia implant. Material and methods Twenty single-rooted mandibular incisors were included, 12 with 1 canal and 8 with 2 canals confirmed by micro-CT. The roots and a zirconia implant were placed into the alveolar sockets of the right and left mandibular central incisors of a dry human mandible, respectively. In total, 240 CBCT scans were obtained using FOV 5 × 5 cm, 90 kVp, with and without an implant, for each root. The variable parameters included the MAR tool, 1 LR-protocol (0.2 mm voxel, 5 mA), and 2 HR-protocols (0.085 mm voxel, 4 and 10 mA). Five calibrated examiners independently evaluated the scans. An ordinal cumulative link mixed model (CLMM) with crossed random intercepts for roots and examiners was used for data analysis (α = 5%).

Results

The CLMM revealed a significant main effect for implant presence (P = .049) and canal status (P < .001), but not for protocol (P = .135) or MAR (P = .392). Significant protocol x canal status (P < .001) and implant x canal status (P < .001) interactions were found, whereas MAR interactions were not significant (P > .05). In 2-canal roots, the zirconia implant significantly induced false-negative shifts under HR-4 (P < .0001) and LR (P < .0001) protocols, whereas HR-10 preserved sensitivity (P = .7760). In single-canal roots, implants induced false-positive shifts in HR-10 (P = .0011) and HR-4 (P = .0011).

Conclusion

Zirconia implants impair second canal detection via false-negative and false-positive errors. High-resolution CBCT (HR-10) should be prioritized to preserve diagnostic sensitivity, whereas MAR offers no clinical benefit and cannot compensate for reduced resolution or exposure. Advances in knowledge CBCT diagnostic performance near zirconia implants relies on acquisition protocol rather than MAR activation. High-resolution CBCT (HR-10) mitigates implant-induced false negatives, whereas lower-resolution or lower-milliamperage protocols compromise diagnostic accuracy.

Schlagwörter

Stichwörter der Autor:innen

Cone Beam Computed TomographyImage ArtifactsImage Enhancement

Autor:innen und Institutionen

  • Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil.
  • Department of Restorative Dentistry, Federal University of Paraná, Curitiba, Paraná, Brazil.

ORCID-Profile: Maria Fernanda Silva Andrade-Bortoletto, Thaísa Pinheiro Silva, Marcela Tarosso Réa, Renata Maira de Souza Leal, Débora Costa Ruiz, Deborah Queiroz Freitas

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Silva Andrade-Bortoletto, M. F., Silva, T. P., Réa, M. T., de Souza Leal, R. M., Costa Ruiz, D., & Freitas, D. Q. (2026). Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twag070

Vancouver

Silva Andrade-Bortoletto MF, Silva TP, Réa MT, de Souza Leal RM, Costa Ruiz D, Freitas DQ. Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant. Dentomaxillofacial Radiology. 2026. doi:10.1093/dmfr/twag070

BibTeX
@article{SilvaAndradeBortoletto2026,
  author = {Silva Andrade-Bortoletto, Maria Fernanda and Silva, Thaísa Pinheiro and Réa, Marcela Tarosso and de Souza Leal, Renata Maira and Costa Ruiz, Débora and Freitas, Deborah Queiroz},
  title = {Diagnostic accuracy of 3 cone-beam CT protocols and metal artifact reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant},
  journal = {Dentomaxillofacial Radiology},
  year = {2026},
  doi = {10.1093/dmfr/twag070}
}
Kostenlos starten →