EUVIMEDEUVIMED entdecken
Crossref

Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography

Débora Costa Ruiz, Larissa de Oliveira Reis, Rocharles Cavalcante Fontenele, Murilo Miranda-Viana, Amanda Farias-Gomes, Deborah Queiroz Freitas

Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology · 2024-02 · 137 (2) · 190-198

DOI: 10.1016/j.oooo.2023.10.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2024-02. Verfasst von Débora Costa Ruiz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Electronic address: ruiz03338@gmail.com. Hauptthemen laut MEDLINE: Tooth Root, Tooth Fractures. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth RootTooth FracturesHumansZirconiumArtifactsCone-Beam Computed TomographyAlgorithms

Substanzen

Zirconium

Autor:innen und Institutionen

  • Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Electronic address: ruiz03338@gmail.com.
  • Department of Dentistry, Federal University of Juiz de Fora Campus Governador Valadares, Governador Valadares, MG, Brazil.
  • OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
  • Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
  • School of Dentistry, Federal University of Mato Grosso do Sul, Campo Grande, Brazil.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Ruiz, D. C., Reis, L. O., Fontenele, R. C., Miranda-Viana, M., Farias-Gomes, A., & Freitas, D. Q. (2024). Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 137(2), 190-198. https://doi.org/10.1016/j.oooo.2023.10.001

Vancouver

Ruiz DC, Reis LO, Fontenele RC, Miranda-Viana M, Farias-Gomes A, Freitas DQ. Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. 2024;137(2):190-198. doi:10.1016/j.oooo.2023.10.001

BibTeX
@article{Ruiz2024,
  author = {Ruiz, Débora Costa and Reis, Larissa de Oliveira and Fontenele, Rocharles Cavalcante and Miranda-Viana, Murilo and Farias-Gomes, Amanda and Freitas, Deborah Queiroz},
  title = {Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography},
  journal = {Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology},
  year = {2024},
  volume = {137},
  number = {2},
  pages = {190--198},
  doi = {10.1016/j.oooo.2023.10.001}
}
Kostenlos starten →