Image quality and radiation dose comparison for abdominopelvic CT studies performed using photon-counting CT and dual-energy CT: a clinical study
BJR|Open · 18.01.2026 · 8 (1)
DOI: 10.1093/bjro/tzag012 ↗Kurz gefasst
Fachartikel in der Zeitschrift BJR|Open, online erschienen am 22.05.2026. Verfasst von Areej Aljabal und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, United States. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Radiological Society of North America, Research & Education Foundation.
Abstract (Originalsprache)
Objectives
To compare radiation dose and image quality of abdominopelvic CT studies performed on dual-energy energy-integrating detector CT (EID-CT) and photo-counting CT (PCCT) for the same patient cohort with clinically aligned protocols.
Methods
An IRB-approved retrospective cohort study included 49 patients who underwent portal venous phase abdominopelvic CT exams using both dual-energy CT and PCCT scanners within a maximum interval of 3 months. Images reconstructed included virtual monoenergetic images at 50, 60, and 70 keV and mixed images. CTDIvol values were recorded to assess radiation dose. Regions of interest were drawn in the 6 anatomical locations for quantitative analysis. The overall image quality, contrast enhancement, image noise, and presence of artifacts were evaluated using a 5-point Likert scale.
Results
No significant differences were observed in image quality scores between PCCT and EID-CT for most comparisons. Calculated contrast-to-noise ratios (CNR) were significantly higher on PCCT except for 70 keV. PCCT demonstrated a significantly lower radiation dose, with an average reduction of 20% ± 15%, up to 51%.
Conclusion
For abdominopelvic CT exams with our institutional protocol settings, PCCT has demonstrated a significant reduction in radiation dose while maintaining similar image quality as EID-CT. Advances in knowledge With clinically aligned protocols for the same cohort of patients, the results provided robust evidence for understanding the benefits of PCCT. It also provided a possible pathway to transit from EID-CT to PCCT in the abdominopelvic imaging.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, United States.
- Department of Medical Imaging, Ministry of National Guard - Health Affairs, Riyadh, Saudi Arabia.
- King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.
- UT Southwestern Medical Center, Dallas, TX 75390, United States.
ORCID-Profile: Liqiang Ren, Xinhui Duan
Förderung
- Radiological Society of North America, Research & Education Foundation
Zitieren
APA
Aljabal, A., Ananthakrishnan, L., Yadu, N., Goel, A., Zeikus, E., Ahn, R., Ren, L., Xi, Y., & Duan, X. (2026). Image quality and radiation dose comparison for abdominopelvic CT studies performed using photon-counting CT and dual-energy CT: a clinical study. BJR|Open, 8(1). https://doi.org/10.1093/bjro/tzag012
Vancouver
Aljabal A, Ananthakrishnan L, Yadu N, Goel A, Zeikus E, Ahn R, et al. Image quality and radiation dose comparison for abdominopelvic CT studies performed using photon-counting CT and dual-energy CT: a clinical study. BJR|Open. 2026;8(1). doi:10.1093/bjro/tzag012
BibTeX
@article{Aljabal2026,
author = {Aljabal, Areej and Ananthakrishnan, Lakshmi and Yadu, Neha and Goel, Anish and Zeikus, Eric and Ahn, Richard and Ren, Liqiang and Xi, Yin and Duan, Xinhui},
title = {Image quality and radiation dose comparison for abdominopelvic CT studies performed using photon-counting CT and dual-energy CT: a clinical study},
journal = {BJR|Open},
year = {2026},
volume = {8},
number = {1},
doi = {10.1093/bjro/tzag012}
}
EUVIMED