Fachartikel in der Zeitschrift British Journal of Radiology, online erschienen am 12.12.2023. Verfasst von Gishan Ratnayake und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane 4102, Australia. Hauptthemen laut MEDLINE: Radiosurgery, Meningioma, Meningeal Neoplasms, Organometallic Compounds. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Elekta AB.
Abstract (Originalsprache)
Objectives
To investigate the impact of adding 68Ga-DOTATATE PET/MRI to standard MRI for target volume delineation in Gamma Knife® stereotactic radiosurgery (GKSRS) for meningioma.
Methods
Seventeen patients with 18 lesions undergoing GKSRS for WHO grade 1 meningioma were enrolled in a prospective study. All patients underwent pre-treatment 68Ga-DOTATATE PET/MRI examination in addition to standard procedures. Five clinicians independently contoured the gross tumour volume (GTV) based on standard MRI (GTVMRI) and PET/MRI (GTVPET/MRI) on separate occasions. Interobserver agreement was evaluated using Cohen’s Kappa statistic (CKS), Dice similarity coefficient (DC), and Hausdorff distance (HD). Statistical analysis was performed with paired t-test and Wilcoxon signed rank test.
Results
The addition of PET/MRI significantly increased GTV contour volume (mean GTVPET/MRI 3.59 cm3 versus mean GTVMRI 3.18 cm3, P = .008). Using the treating clinician’s pre-treatment GTVMRI as the reference, median CKS (87.2 vs 77.5, P = .006) and DC (87.2 vs 77.4, P = .006) were significantly lower, and median HD (25.2 vs 31.0, P = .001) was significantly higher with the addition of PET/MRI. No significant difference was observed in interobserver contouring reproducibility between GTVMRI and GTVPET/MRI.
Conclusion
The addition of 68Ga-DOTATATE PET/MRI for target volume delineation in GKSRS for meningioma is associated with an increase in GTV volume and greater interobserver variation. PET/MRI did not affect interobserver contouring reproducibility. Advances in Knowledge This study provides novel insights into the impact of 68Ga-DOTATATE PET/MRI on GTV delineation and interobserver agreement in meningioma GKSRS, highlighting its potential for improving GKSRS treatment accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane 4102, Australia.
- Faculty of Medicine, University of Queensland, Brisbane 4006, Australia.
- Department of Medical Imaging, Princess Alexandra Hospital, Brisbane 4102, Australia.
- Department of Neurosurgery, Princess Alexandra Hospital, Brisbane 4102, Australia.
ORCID-Profile: Gishan Ratnayake
Förderung
- Elekta AB
Zitieren
APA
Ratnayake, G., Huo, M., Mehta, A., Ramachandran, P., Pinkham, M. B., Law, P., Watkins, T., Olson, S., Hall, B., Brown, S., Lusk, R., Jones, C., O'Mahoney, E., McGill, G., & Foote, M. C. (2024). Utility of 68Ga-DOTATATE PET-MRI for Gamma Knife® stereotactic radiosurgery treatment planning for meningioma. British Journal of Radiology, 97(1153), 180-185. https://doi.org/10.1093/bjr/tqad026
Vancouver
Ratnayake G, Huo M, Mehta A, Ramachandran P, Pinkham MB, Law P, et al. Utility of 68Ga-DOTATATE PET-MRI for Gamma Knife® stereotactic radiosurgery treatment planning for meningioma. British Journal of Radiology. 2024;97(1153):180-185. doi:10.1093/bjr/tqad026
BibTeX
@article{Ratnayake2024,
author = {Ratnayake, Gishan and Huo, Michael and Mehta, Akash and Ramachandran, Prabhakar and Pinkham, Mark B and Law, Phillip and Watkins, Trevor and Olson, Sarah and Hall, Bruce and Brown, Simon and Lusk, Ryan and Jones, Catherine and O'Mahoney, Eoin and McGill, George and Foote, Matthew C},
title = {Utility of 68Ga-DOTATATE PET-MRI for Gamma Knife® stereotactic radiosurgery treatment planning for meningioma},
journal = {British Journal of Radiology},
year = {2024},
volume = {97},
number = {1153},
pages = {180--185},
doi = {10.1093/bjr/tqad026}
}
EUVIMED