EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Calculating optic nerve planning organ at risk volume margins for stereotactic radiosurgery using optic nerve motion determined using MRI

Sagar Sabharwal, Geoff Heyes iD, George S J Tudor, Robert Flintham, Swarupsinh Chavda, Paul Sanghera

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqae201 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Sagar Sabharwal und 5 weiteren Autor:innen. Beteiligte Einrichtung: Dept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom. Hauptthemen laut MEDLINE: Radiosurgery, Optic Nerve, Magnetic Resonance Imaging, Organs at Risk. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The combination of sharp dose gradients in stereotactic radiosurgery (SRS) and minute optic nerve motion may significantly increase dose to the optic nerves when treating perioptic lesions. The aim of this study was to calculate optic nerve planning organ at risk volume (PRV) margins for CyberKnife SRS treatment planning.

Methods

MRI scans were taken of 10 healthy volunteers looking left, right, up, down, and straight ahead to measure optic nerve motion. The measured optic nerve motion and the uncertainties in the technical accuracy of CyberKnife were used to calculate optic nerve PRV margins.

Results

Two optic nerve PRV margins were calculated: a non-isotropic margin of mL/R,PRV=3 mm, mSup/Inf,PRV=2 mm, and mAnt/Post,PRV=1 mm which considers the full range of motion measured in a worst case scenario; and an isotropic margin of mPRV=1 mm which considers a scenario where patients are asked to look neutrally during imaging and treatment. Applying these PRVs to 8 historical sphenoid wing meningioma CyberKnife plans showed tolerance levels may be exceeded due to optic nerve motion.

Conclusions

Optic nerve PRV margins may be needed in CyberKnife planning to reduce risk to the optic nerves. The use of a mPRV=1 mm PRV to account for organ motion, along with instructing patients to hold their gaze neutrally during imaging and treatment, may be a suitable organ sparing strategy. Advances in knowledge Measured optic nerve motion and the technical accuracy of the CyberKnife system have been used to calculate optic nerve PRV margins.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryOptic NerveMagnetic Resonance ImagingOrgans at RiskHumansMaleFemaleAdultMeningiomaRadiotherapy Planning, Computer-AssistedHealthy VolunteersMeningeal Neoplasms

Stichwörter der Autor:innen

MRIPRV marginscyberknifeoptic nerve motionradiotherapystereotactic radiosurgery

Autor:innen und Institutionen

  • Dept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
  • Dept Physics, University of Birmingham, Birmingham, B152TT, United Kingdom.
  • Dept Radiology, University Hospitals NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
  • Dept Oncology, University Hospitals NHS Foundation Trust, Birmingham, B152TH, United Kingdom.

ORCID-Profile: Geoff Heyes

Zitieren

APA

Sabharwal, S., Heyes, G., Tudor, G. S. J., Flintham, R., Chavda, S., & Sanghera, P. (2025). Calculating optic nerve planning organ at risk volume margins for stereotactic radiosurgery using optic nerve motion determined using MRI. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae201

Vancouver

Sabharwal S, Heyes G, Tudor GSJ, Flintham R, Chavda S, Sanghera P. Calculating optic nerve planning organ at risk volume margins for stereotactic radiosurgery using optic nerve motion determined using MRI. British Journal of Radiology. 2025. doi:10.1093/bjr/tqae201

BibTeX
@article{Sabharwal2025,
  author = {Sabharwal, Sagar and Heyes, Geoff and Tudor, George S J and Flintham, Robert and Chavda, Swarupsinh and Sanghera, Paul},
  title = {Calculating optic nerve planning organ at risk volume margins for stereotactic radiosurgery using optic nerve motion determined using MRI},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqae201}
}
Kostenlos starten →