EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Repeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas

Jan Saip Aunan-Diop iD, Ancuta Ioana Friismose iD, Bo Halle iD, Christian Bonde Pedersen iD, Bo Mussmann iD, Emi Hojo iD, Ziying Yin iD, Mathias Just Nortvig iD, Kerstin Lagerstrand iD, Frantz Rom Poulsen iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29825 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Jan Saip Aunan-Diop und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Odense University Hospital, Odense, Denmark. Hauptthemen laut MEDLINE: Meningioma, Elasticity Imaging Techniques, Meningeal Neoplasms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, Kræftens Bekæmpelse.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance elastography (MRE) quantifies tissue viscoelasticity, offering insights into intracranial meningiomas. MRE‐derived parameters, including the storage modulus ( G ') and the magnitude of the complex modulus (| G *|), may aid neurosurgical planning, but their repeatability remains unexplored in brain tumors. Purpose/Hypothesis To evaluate the repeatability of G ' and | G *| in meningiomas, the influence of tumor volume and spatial location on variability, and ranking stability across paired elastograms. Study Type Prospective. Population/Subjects Seventeen paired MRE scans from 16 patients with meningiomas (mean age 64 ± 12 years, 10 females) scheduled for resection. Field Strength/Sequence MRE was performed on a 3 T system using a single‐shot spin‐echo echo‐planar imaging (SE‐EPI) sequence. Assessment Tumors were segmented on contrast‐enhanced T1‐weighted images; distance and volume metrics were extracted. Regions of interest were applied to G ' and | G *| elastograms. Repeatability was evaluated using the coefficient of variation (CV%). Ranking stability was assessed by comparing median G ' or | G *| values. Statistical Tests The difference in CV% was assessed using the Wilcoxon signed rank test. Linear regression assessed the effect of tumor volume and distance from the external occipital protuberance (EOP) on CV%. The Wilcoxon signed‐rank test evaluated ranking stability and scan‐rescan CV%. Statistical significance was defined as p < 0.05.

Results

The difference in CV% G' (14.89 ± 12.32) and CV% | G *| (13.88 ± 12.60) was not significant ( p = 0.61). Tumor volume inversely correlated with CV% ( G ': β = −0.75 | G *|: β = −0.59). Tumor‐EOP distance had no significant effect ( G ': p = 0.58, | G *|: p = 0.23). Rankings remained stable ( G ': p = 0.82, | G *|: p = 0.71). Data Conclusion MRE‐derived parameters are repeatable in intracranial meningiomas, with G ' and | G *| being equally stable. Larger tumors yielded more consistent estimates. Preserved ranking stability supports the use of MRE in preoperative planning. Evidence Level 2. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MeningiomaElasticity Imaging TechniquesMeningeal NeoplasmsMagnetic Resonance ImagingHumansFemaleMiddle AgedMaleReproducibility of ResultsProspective StudiesAgedEcho-Planar ImagingAdultElastic Modulus

Stichwörter der Autor:innen

magnetic resonance elastographymeningiomasneurosurgeryrepeatabilityviscoelasticity

Autor:innen und Institutionen

  • Department of Neurosurgery, Odense University Hospital, Odense, Denmark.
  • Department of Clinical Research, University of Southern Denmark, BRIDGE (Brain Research Inter Disciplinary Guided Excellence), University of Southern Denmark, Odense, Denmark.
  • Department of Radiology, Odense University Hospital, Odense, Denmark.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Medical Physics and Biomedical Engineering, Sahlgrenska, University Hospital, Gothenburg, Sweden.
  • Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

ORCID-Profile: Jan Saip Aunan-Diop, Ancuta Ioana Friismose, Bo Halle, Christian Bonde Pedersen, Bo Mussmann, Emi Hojo, Ziying Yin, Mathias Just Nortvig, Kerstin Lagerstrand, Frantz Rom Poulsen

Förderung

  • NINDS NIH HHS
  • NIBIB NIH HHS
  • Kræftens Bekæmpelse

Zitieren

APA

Aunan-Diop, J. S., Friismose, A. I., Halle, B., Pedersen, C. B., Mussmann, B., Hojo, E., Yin, Z., Nortvig, M. J., Lagerstrand, K., & Poulsen, F. R. (2025). Repeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29825

Vancouver

Aunan-Diop JS, Friismose AI, Halle B, Pedersen CB, Mussmann B, Hojo E, et al. Repeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29825

BibTeX
@article{AunanDiop2025,
  author = {Aunan-Diop, Jan Saip and Friismose, Ancuta Ioana and Halle, Bo and Pedersen, Christian Bonde and Mussmann, Bo and Hojo, Emi and Yin, Ziying and Nortvig, Mathias Just and Lagerstrand, Kerstin and Poulsen, Frantz Rom},
  title = {Repeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29825}
}
Kostenlos starten →