Improving transportability of regression calibration under the main/external validation study design
Biometrics · 2026
DOI: 10.1093/biomtc/ujag019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biometrics, 2026. Verfasst von Zexiang Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biostatistics, Yale School of Public Health, New Haven, Connecticut 06510, United States. Hauptthemen laut MEDLINE: Validation Studies as Topic. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIEHS NIH HHS, NIH HHS.
Abstract (Originalsprache)
In epidemiology, exposures are usually subject to measurement error (ME). Regression calibration with a validation study is widely employed as an analysis method to correct for ME in the main study (MS) due to its broad applicability and simple implementation. However, relying on an external validation study (EVS) carries the risk of introducing bias into the analysis. Specifically, if the parameters of the regression calibration model estimated from the EVS are not transportable to the MS, the subsequent estimator of the parameter will be biased. In this work, we improve the regression calibration method for linear regression models using an external validation study. Unlike the standard approach, our method ensures that the regression calibration model is transportable by estimating the parameters in the ME generating process using the external validation study and obtaining the remaining parameter values in the regression calibration model directly from the MS. This guarantees that parameter values in the regression calibration model will be applicable to the MS. We derived the theoretical properties of our method. The simulation results show that our method effectively reduces bias and maintains nominal confidence interval coverage. We applied this method to data from the Health Professionals Follow-Up Study and the Men’s Lifestyle Validation Study to assess the effects of dietary intake on body weight.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biostatistics, Yale School of Public Health, New Haven, Connecticut 06510, United States.
- Center for Methods in Implementation and Prevention Science, Yale School of Public Health, New Haven, Connecticut 06510, United States.
- Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, Massachusetts 02115, United States.
- Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, Massachusetts 02115, United States.
- Channing Division of Network Medicine, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts 02115, United States.
- Department of Biomedical Informatics & Data Science, Yale School of Medicine, New Haven, Connecticut 06510, United States.
ORCID-Profile: Donna Spiegelman, Molin Wang, Zuoheng Wang, Xin Zhou
Förderung
- NCI NIH HHS
- NIEHS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Li, Z., Spiegelman, D., Wang, M., Wang, Z., & Zhou, X. (2026). Improving transportability of regression calibration under the main/external validation study design. Biometrics. https://doi.org/10.1093/biomtc/ujag019
Vancouver
Li Z, Spiegelman D, Wang M, Wang Z, Zhou X. Improving transportability of regression calibration under the main/external validation study design. Biometrics. 2026. doi:10.1093/biomtc/ujag019
BibTeX
@article{Li2026,
author = {Li, Zexiang and Spiegelman, Donna and Wang, Molin and Wang, Zuoheng and Zhou, Xin},
title = {Improving transportability of regression calibration under the main/external validation study design},
journal = {Biometrics},
year = {2026},
doi = {10.1093/biomtc/ujag019}
}
EUVIMED