EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Debiased high-dimensional regression calibration for errors-in-variables log-contrast models

Huali Zhao iD, Tianying Wang iD

Biometrics · 2024

DOI: 10.1093/biomtc/ujae153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biometrics, 2024. Verfasst von Huali Zhao und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mathematical Sciences, Tsinghua University, Beijing 100084, China. Hauptthemen laut MEDLINE: Models, Statistical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Motivated by the challenges in analyzing gut microbiome and metagenomic data, this work aims to tackle the issue of measurement errors in high-dimensional regression models that involve compositional covariates. This paper marks a pioneering effort in conducting statistical inference on high-dimensional compositional data affected by mismeasured or contaminated data. We introduce a calibration approach tailored for the linear log-contrast model. Under relatively lenient conditions regarding the sparsity level of the parameter, we have established the asymptotic normality of the estimator for inference. Numerical experiments and an application in microbiome study have demonstrated the efficacy of our high-dimensional calibration strategy in minimizing bias and achieving the expected coverage rates for confidence intervals. Moreover, the potential application of our proposed methodology extends well beyond compositional data, suggesting its adaptability for a wide range of research contexts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, StatisticalHumansCalibrationGastrointestinal MicrobiomeComputer SimulationRegression AnalysisBiasLinear ModelsBiometryData Interpretation, StatisticalMetagenomics

Stichwörter der Autor:innen

Lasso-based inferencecompositional datameasurement error analysisregression calibration

Autor:innen und Institutionen

  • Department of Mathematical Sciences, Tsinghua University, Beijing 100084, China.
  • Department of Statistics, Colorado State University, Fort Collins, CO 80523, United States.

ORCID-Profile: Huali Zhao, Tianying Wang

Zitieren

APA

Zhao, H., & Wang, T. (2024). Debiased high-dimensional regression calibration for errors-in-variables log-contrast models. Biometrics. https://doi.org/10.1093/biomtc/ujae153

Vancouver

Zhao H, Wang T. Debiased high-dimensional regression calibration for errors-in-variables log-contrast models. Biometrics. 2024. doi:10.1093/biomtc/ujae153

BibTeX
@article{Zhao2024,
  author = {Zhao, Huali and Wang, Tianying},
  title = {Debiased high-dimensional regression calibration for errors-in-variables log-contrast models},
  journal = {Biometrics},
  year = {2024},
  doi = {10.1093/biomtc/ujae153}
}
Kostenlos starten →