EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Multiple bias calibration for valid statistical inference under nonignorable nonresponse

Seonghun Cho, Jae Kwang Kim iD, Yumou Qiu iD

Biometrics · 2025

DOI: 10.1093/biomtc/ujaf044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biometrics, 2025. Verfasst von Seonghun Cho und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Statistics, Inha University, Incheon 22212, Korea. Hauptthemen laut MEDLINE: Models, Statistical, Biometry. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea, MSIT, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Valid statistical inference is notoriously challenging when the sample is subject to nonresponse bias. We approach this difficult problem by employing multiple candidate models for the propensity score (PS) function combined with empirical likelihood. By incorporating multiple working PS models into the internal bias calibration constraint in the empirical likelihood, the selection bias can be safely eliminated as long as the working PS models contain the true model and their expectations are equal to the true missing rate. The bias calibration constraint for the multiple PS models is called the multiple bias calibration. The study delves into the asymptotic properties of the proposed method and provides a comparative analysis through limited simulation studies against existing methods. To illustrate practical implementation, we present a real data analysis on body fat percentage using the National Health and Nutrition Examination Survey dataset.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, StatisticalBiometryHumansBiasComputer SimulationData Interpretation, StatisticalCalibrationNutrition SurveysPropensity ScoreLikelihood Functions

Stichwörter der Autor:innen

calibrationempirical likelihoodmissing not at randommultiply robust estimationpropensity scoreselection bias

Autor:innen und Institutionen

  • Department of Statistics, Inha University, Incheon 22212, Korea.
  • Department of Statistics, Iowa State University, Ames, IA 50011, United States.
  • School of Mathematical Sciences and Center for Statistical Science, Peking University, Beijing 100871, China.

ORCID-Profile: Jae Kwang Kim, Yumou Qiu

Förderung

  • National Research Foundation of Korea
  • MSIT
  • National Natural Science Foundation of China
  • National Science Foundation
  • U.S. Department of Agriculture

Zitieren

APA

Cho, S., Kim, J. K., & Qiu, Y. (2025). Multiple bias calibration for valid statistical inference under nonignorable nonresponse. Biometrics. https://doi.org/10.1093/biomtc/ujaf044

Vancouver

Cho S, Kim JK, Qiu Y. Multiple bias calibration for valid statistical inference under nonignorable nonresponse. Biometrics. 2025. doi:10.1093/biomtc/ujaf044

BibTeX
@article{Cho2025,
  author = {Cho, Seonghun and Kim, Jae Kwang and Qiu, Yumou},
  title = {Multiple bias calibration for valid statistical inference under nonignorable nonresponse},
  journal = {Biometrics},
  year = {2025},
  doi = {10.1093/biomtc/ujaf044}
}
Kostenlos starten →