EUVIMEDEUVIMED entdecken
Systematische Übersicht

Suture material in pancreticojejunal anastomosis: a systematic review

Douglas Chung iD, Supun Bakmiwewa, Arul Suthananthan, Marwan Idrees iD

ANZ Journal of Surgery · 2025

DOI: 10.1111/ans.19408 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift ANZ Journal of Surgery, 2025. Verfasst von Douglas Chung und 3 weiteren Autor:innen. Beteiligte Einrichtung: General Surgical Department, Liverpool Hospital, Corner of Elizabeth and Goulburn Street, Liverpool, New South Wales, 2170, Australia. Hauptthemen laut MEDLINE: Sutures, Pancreaticojejunostomy, Pancreatic Fistula, Suture Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Post‐operative pancreatic fistula is a common and morbid complication of pancreaticojejunal anastomosis. While gastrointestinal anastomosis is typically performed using absorbable sutures, this issue has prompted experimentation with non‐absorbable sutures. This study aims to assess the available literature to provide recommendations on suture choice in this anastomosis.

Methods

Two independent reviewers performed searches of EMBASE, MEDLINE, PubMed, Google Scholar, and the Cochrane Library of Systematic Review. References were screened for additional articles. Articles comparatively assessing suture choice in pancreaticojejunal anastomosis were included.

Results

Of 2237 records screened, nine articles were included in this review. Suture materials assessed include polydioxanone, polyglactin 910, polyglycolic acid, polypropylene, polyester, silk, nylon, plain and chromic catgut, and polybutester. Clinical studies suggested polyester reduced rates of fistula formation. Ex vivo findings favoured polydioxanone and polyglactin 910. 5–0 was found to be favourable to 6–0 in duct‐to‐mucosa anastomosis with monofilament absorbable sutures. Barbed sutures were suggested to reduce fistula formation. Limitations were identified in many of the included articles.

Conclusion

There is limited research available on this topic, and it is not possible to strongly recommend any single suture as superior to others. Polyester is promising in clinical studies, and would benefit from further studies assessing validity. Polydioxanone and polyglactin 910 have rational indications for use. In particular, polydioxanone is suggested when poor healing is expected. Barbed sutures may reduce rates of fistula formation. More research is required to draw a strong conclusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SuturesPancreaticojejunostomyPancreatic FistulaSuture TechniquesHumansPolydioxanoneAnastomosis, SurgicalPolyglactin 910Postoperative Complications

Stichwörter der Autor:innen

pancreaspancreatic fistulapancreaticojejunostomysuture techniquessutures

Substanzen

PolydioxanonePolyglactin 910

Autor:innen und Institutionen

  • General Surgical Department, Liverpool Hospital, Corner of Elizabeth and Goulburn Street, Liverpool, New South Wales, 2170, Australia.
  • General Surgical Department, Sir Charles Gairdner Hospital, Perth, Western Australia, Australia.

ORCID-Profile: Douglas Chung, Marwan Idrees

Zitieren

APA

Chung, D., Bakmiwewa, S., Suthananthan, A., & Idrees, M. (2025). Suture material in pancreticojejunal anastomosis: a systematic review. ANZ Journal of Surgery. https://doi.org/10.1111/ans.19408

Vancouver

Chung D, Bakmiwewa S, Suthananthan A, Idrees M. Suture material in pancreticojejunal anastomosis: a systematic review. ANZ Journal of Surgery. 2025. doi:10.1111/ans.19408

BibTeX
@article{Chung2025,
  author = {Chung, Douglas and Bakmiwewa, Supun and Suthananthan, Arul and Idrees, Marwan},
  title = {Suture material in pancreticojejunal anastomosis: a systematic review},
  journal = {ANZ Journal of Surgery},
  year = {2025},
  doi = {10.1111/ans.19408}
}
Kostenlos starten →