Sensitivity Analysis of a Physiologically Based Pharmacokinetic Model Used for Treatment Planning in Peptide Receptor Radionuclide Therapy
Cancer Biotherapy and Radiopharmaceuticals · 2016-08 · 31 (6) · 217-224
DOI: 10.1089/cbr.2016.2012 ↗At a glance
Journal article in Cancer Biotherapy and Radiopharmaceuticals, 2016-08. Written by Deni Hardiansyah and 4 co-authors. Institution: 1 Medical Radiation Physics/Radiation Protection, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University , Mannheim, Germany. Major MEDLINE topics: Models, Biological. Cited 10 times so far (Crossref); 29 references.
Abstract (original language)
The aim of this work was to evaluate the sensitivity of time-integrated activity coefficients (TIACs) on the erroneously chosen prior knowledge in a physiologically based pharmacokinetic (PBPK) model used for treatment planning in peptide receptor radionuclide therapy (PRRT). Parameters of the PBPK model were fitted to the biokinetic data of 15 patients after the injection of (111)In-DTPAOC. The fittings were performed using fixed parameter values taken from literature as prior knowledge (reference case, Ref). The fixed parameters were gender, physical information (e.g., body weight), dissociation rate koff, dissociation constant KD, fraction of blood flow, and spleen and liver volumes. The fittings were repeated with changed fixed parameters (Changed). The relative deviations (RDs) of TIACs calculated from Changed and Ref were analyzed for kidneys, tumor, liver, spleen, remainder, whole body, and serum. A changed koff has the largest effect on RD, the largest RD values were found for changed koff = 0.001 L/min: RDkidneys = (3 ± 3)%, RDtumor = (0.5 ± 4)%, RDliver = (6 ± 9)%, RDspleen = (5 ± 5)%, RDremainder = (2 ± 31)%, RDserum = (-4 ± 25)%, and RDwholebody = (3 ± 16)%. For other changed parameters, the maximum RDs were
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- 1 Medical Radiation Physics/Radiation Protection, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University , Mannheim, Germany .
- 2 Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University , Mannheim, Germany .
- 3 Digitale Signalverarbeitung , Information Technology Faculty, Hochschule Mannheim, Mannheim, Germany .
- 4 Department of Nuclear Medicine, University Hospital Ulm , Ulm, Germany .
- 5 Klinik für Nuklearmedizin, University Hospital, RWTH Aachen University , Aachen, Germany .
- 6 Department of Nuclear Medicine, Maastricht University Medical Center (MUMC+) , Maastricht, The Netherlands .
Cite
APA
Hardiansyah, D., Begum, N. J., Kletting, P., Mottaghy, F. M., & Glatting, G. (2016). Sensitivity Analysis of a Physiologically Based Pharmacokinetic Model Used for Treatment Planning in Peptide Receptor Radionuclide Therapy. Cancer Biotherapy and Radiopharmaceuticals, 31(6), 217-224. https://doi.org/10.1089/cbr.2016.2012
Vancouver
Hardiansyah D, Begum NJ, Kletting P, Mottaghy FM, Glatting G. Sensitivity Analysis of a Physiologically Based Pharmacokinetic Model Used for Treatment Planning in Peptide Receptor Radionuclide Therapy. Cancer Biotherapy and Radiopharmaceuticals. 2016;31(6):217-224. doi:10.1089/cbr.2016.2012
BibTeX
@article{Hardiansyah2016,
author = {Hardiansyah, Deni and Begum, Nusrat Jihan and Kletting, Peter and Mottaghy, Felix M and Glatting, Gerhard},
title = {Sensitivity Analysis of a Physiologically Based Pharmacokinetic Model Used for Treatment Planning in Peptide Receptor Radionuclide Therapy},
journal = {Cancer Biotherapy and Radiopharmaceuticals},
year = {2016},
volume = {31},
number = {6},
pages = {217--224},
doi = {10.1089/cbr.2016.2012}
}
EUVIMED