Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2024. Verfasst von Zahra Mansouri und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland. Hauptthemen laut MEDLINE: Octreotide, Organometallic Compounds, Single Photon Emission Computed Tomography Computed Tomography, Radiometry. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Euratom, University of Geneva.
Abstract (Originalsprache)
Purpose
Accurate dosimetry is critical for ensuring the safety and efficacy of radiopharmaceutical therapies. In current clinical dosimetry practice, MIRD formalisms are widely employed. However, with the rapid advancement of deep learning (DL) algorithms, there has been an increasing interest in leveraging the calculation speed and automation capabilities for different tasks. We aimed to develop a hybrid transformer-based deep learning (DL) model that incorporates a multiple voxel S -value (MSV) approach for voxel-level dosimetry in [ 177 Lu]Lu-DOTATATE therapy. The goal was to enhance the performance of the model to achieve accuracy levels closely aligned with Monte Carlo (MC) simulations, considered as the standard of reference. We extended our analysis to include MIRD formalisms (SSV and MSV), thereby conducting a comprehensive dosimetry study.
Methods
We used a dataset consisting of 22 patients undergoing up to 4 cycles of [ 177 Lu]Lu-DOTATATE therapy. MC simulations were used to generate reference absorbed dose maps. In addition, MIRD formalism approaches, namely, single S -value (SSV) and MSV techniques, were performed. A UNEt TRansformer (UNETR) DL architecture was trained using five-fold cross-validation to generate MC-based dose maps. Co-registered CT images were fed into the network as input, whereas the difference between MC and MSV (MC-MSV) was set as output. DL results are then integrated to MSV to revive the MC dose maps. Finally, the dose maps generated by MSV, SSV, and DL were quantitatively compared to the MC reference at both voxel level and organ level (organs at risk and lesions).
Results
The DL approach showed slightly better performance (voxel relative absolute error (RAE) = 5.28 ± 1.32) compared to MSV (voxel RAE = 5.54 ± 1.4) and outperformed SSV (voxel RAE = 7.8 ± 3.02). Gamma analysis pass rates were 99.0 ± 1.2%, 98.8 ± 1.3%, and 98.7 ± 1.52% for DL, MSV, and SSV approaches, respectively. The computational time for MC was the highest (~2 days for a single-bed SPECT study) compared to MSV, SSV, and DL, whereas the DL-based approach outperformed the other approaches in terms of time efficiency (3 s for a single-bed SPECT). Organ-wise analysis showed absolute percent errors of 1.44 ± 3.05%, 1.18 ± 2.65%, and 1.15 ± 2.5% for SSV, MSV, and DL approaches, respectively, in lesion-absorbed doses.
Conclusion
A hybrid transformer-based deep learning model was developed for fast and accurate dose map generation, outperforming the MIRD approaches, specifically in heterogenous regions. The model achieved accuracy close to MC gold standard and has potential for clinical implementation for use on large-scale datasets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
- Department of Radiology, University of British Columbia, Vancouver, BC, Canada.
- Cancer Research Centre and Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, QC, Canada.
- Division of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland. habib.zaidi@hcuge.ch.
- Department of Nuclear Medicine, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, Netherlands. habib.zaidi@hcuge.ch.
- Department of Nuclear Medicine, University of Southern Denmark, DK-500, Odense, Denmark. habib.zaidi@hcuge.ch.
ORCID-Profile: Habib Zaidi
Förderung
- H2020 Euratom
- University of Geneva
Zitieren
APA
Mansouri, Z., Salimi, Y., Akhavanallaf, A., Shiri, I., Teixeira, E. P. A., Hou, X., Beauregard, J. M., Rahmim, A., & Zaidi, H. (2024). Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu]Lu-DOTATATE radiopharmaceutical therapy. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-024-06618-9
Vancouver
Mansouri Z, Salimi Y, Akhavanallaf A, Shiri I, Teixeira EPA, Hou X, et al. Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu]Lu-DOTATATE radiopharmaceutical therapy. European Journal of Nuclear Medicine and Molecular Imaging. 2024. doi:10.1007/s00259-024-06618-9
BibTeX
@article{Mansouri2024,
author = {Mansouri, Zahra and Salimi, Yazdan and Akhavanallaf, Azadeh and Shiri, Isaac and Teixeira, Eliluane Pirazzo Andrade and Hou, Xinchi and Beauregard, Jean-Mathieu and Rahmim, Arman and Zaidi, Habib},
title = {Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu]Lu-DOTATATE radiopharmaceutical therapy},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2024},
doi = {10.1007/s00259-024-06618-9}
}
EUVIMED