EUVIMEDEUVIMED entdecken
Validierungsstudie

Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample

Mohamed Nihal P iD, Debasish Mohapatra, Alam Mohd Adil Alam Manir, Vancha Harish iD, Sachin Kumar Singh, Sakshi Upendra Lad, Srinivas Sutrapu, Sumant Saini, Sharfuddin Mohd iD

ASSAY and Drug Development Technologies · 2024-12 · 22 (8) · 409-424

DOI: 10.1089/adt.2024.050 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift ASSAY and Drug Development Technologies, online erschienen am 11.12.2024. Verfasst von Mohamed Nihal P und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, India. Hauptthemen laut MEDLINE: Chalcones, Chromatography, Reverse-Phase. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The primary objective of the present investigation is to develop and validate a simple, robust, and cost-effective isocratic reverse phase-high-performance liquid chromatography (RP-HPLC) method for determining isoliquiritigenin (ISL) in both bulk and biological samples using an analytical quality-by-design (AQbD) approach. The central composite design was employed for method optimization using Design Expert® software, by taking mobile phase ratio and flow rate as independent variables and peak area, retention time, tailing factor, and theoretical plates as dependent variables. The design suggested the use of a mobile phase consisting of acetonitrile:0.2% ortho-phosphoric acid (75:25, v/v) and a flow rate of 0.9 mL/min as optimal chromatographic conditions. The detection of ISL was performed at 364 nm. The optimized method was validated in accordance with International Conference on Harmonization (ICH) Q2(R1) guidelines. The method showed excellent linearity, limit of detection, limit of quantification, accuracy, precision, robustness, and system suitability. All validation parameters fell within the acceptable limits set by ICH. Additionally, the applicability of the method in biological samples were analyzed. In conclusion, the results suggest that the developed and validated AQbD-based RP-HPLC method was well-suited for the estimation of ISL in bulk and biological sample.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChalconesChromatography, Reverse-PhaseChromatography, High Pressure LiquidLimit of Detection

Stichwörter der Autor:innen

CCDRP-HPLCanalytical quality-by-designbioanalytical methodisoliquiritigeninvalidation

Substanzen

Chalconesisoliquiritigenin

Autor:innen und Institutionen

  • School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, India.

ORCID-Profile: Mohamed Nihal P, Vancha Harish, Sharfuddin Mohd

Zitieren

APA

Nihal P, M., Mohapatra, D., Manir, A. M. A. A., Harish, V., Singh, S. K., Lad, S. U., Sutrapu, S., Saini, S., & Mohd, S. (2024). Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample. ASSAY and Drug Development Technologies, 22(8), 409-424. https://doi.org/10.1089/adt.2024.050

Vancouver

Nihal P M, Mohapatra D, Manir AMAA, Harish V, Singh SK, Lad SU, et al. Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample. ASSAY and Drug Development Technologies. 2024;22(8):409-424. doi:10.1089/adt.2024.050

BibTeX
@article{NihalP2024,
  author = {Nihal P, Mohamed and Mohapatra, Debasish and Manir, Alam Mohd Adil Alam and Harish, Vancha and Singh, Sachin Kumar and Lad, Sakshi Upendra and Sutrapu, Srinivas and Saini, Sumant and Mohd, Sharfuddin},
  title = {Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample},
  journal = {ASSAY and Drug Development Technologies},
  year = {2024},
  volume = {22},
  number = {8},
  pages = {409--424},
  doi = {10.1089/adt.2024.050}
}
Kostenlos starten →