EUVIMEDEUVIMED entdecken
Crossref

Stability Indicating Reverse Phase High‐Performance Liquid Chromatographic Method of Isoliquiritigenin: Development, Validation, and Forced Degradation Studies

Abul Barkat M D Tufail Ahmed, Vancha Harish iD, Sharfuddin Mohd iD

Biomedical Chromatography · 2026-04 · 40 (4)

DOI: 10.1002/bmc.70422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 10.03.2026. Verfasst von Abul Barkat M D Tufail Ahmed und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, India. Hauptthemen laut MEDLINE: Chalcones, Chromatography, Reverse-Phase. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple, stability‐indicating RP‐HPLC method was developed to estimate isoliquiritigenin (ISL) and assess its stability under acid, alkaline, oxidative, thermal, and UV stress conditions. Chromatographic separation was performed on a C18 column using UV–visible detection and a 20 μL injection volume, applying an isocratic elution approach to develop and optimize a method for quantifying ISL in stressed samples. At a constant flow rate of 1 mL/min, the mobile phase consisted of 0.1% v/v formic acid (aqueous) and acetonitrile (organic) in a 25:75 ratio. The maximum absorption wavelength ( λ max ) of ISL was found to be 361 nm. According to ICH Q2(R2) guidelines, the method was validated and showed linearity in the 2–10 μg/mL range ( R = 0.9985) with high accuracy (98.38%–99.48% recovery) and precision (% RSD < 2%). Quantification and detection limits were 1.81 and 0.66 μg/mL, respectively. According to forced degradation testing, there was very little deterioration when subjected to thermal and photolytic stress, but there was considerable degradation when exposed to alkaline (93.40%), acidic (98.76%), and oxidative stress (63.80%) at 70°C. The developed method effectively evaluates ISL stability in both bulk and stressed conditions, supporting its use in routine quality control and pharmaceutical formulation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChalconesChromatography, Reverse-PhaseChromatography, High Pressure LiquidReproducibility of ResultsDrug StabilityLimit of DetectionLinear Models

Stichwörter der Autor:innen

ICH Q2(R2) guidelinesRP‐HPLCforced degradationisoliquiritigenin (ISL)method validationstability‐indicating method

Substanzen

isoliquiritigeninChalcones

Autor:innen und Institutionen

  • School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, India.

ORCID-Profile: Vancha Harish, Sharfuddin Mohd

Zitieren

APA

Ahmed, A. B. M. D. T., Harish, V., & Mohd, S. (2026). Stability Indicating Reverse Phase High‐Performance Liquid Chromatographic Method of Isoliquiritigenin: Development, Validation, and Forced Degradation Studies. Biomedical Chromatography, 40(4). https://doi.org/10.1002/bmc.70422

Vancouver

Ahmed ABMDT, Harish V, Mohd S. Stability Indicating Reverse Phase High‐Performance Liquid Chromatographic Method of Isoliquiritigenin: Development, Validation, and Forced Degradation Studies. Biomedical Chromatography. 2026;40(4). doi:10.1002/bmc.70422

BibTeX
@article{Ahmed2026,
  author = {Ahmed, Abul Barkat M D Tufail and Harish, Vancha and Mohd, Sharfuddin},
  title = {Stability Indicating Reverse Phase High‐Performance Liquid Chromatographic Method of Isoliquiritigenin: Development, Validation, and Forced Degradation Studies},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {4},
  doi = {10.1002/bmc.70422}
}
Kostenlos starten →