RadCalc 3D Monte-Carlo: tuning and independent dosimetric validation of radiotherapy treatment plans
Biomedical Physics & Engineering Express · 01.12.2026 · 12 (6) · 065029
DOI: 10.1088/2057-1976/aec16e ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 19.11.2026. Verfasst von Francesco Caridi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Dipartimento di Scienze Matematiche e Informatiche, Scienze Fisiche e Scienze della Terra, Università degli Studi di Messina, V.le F. Stagno D'Alcont…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Monte Carlo Method, Software, Radiometry. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective. This work aimed at implementing a new recalculation software, ‘RadCalc’ (LAP GmbH Laser Applikationen), independent of the monitor units (MUs) and dosimetric verification of the radiotherapy treatment plans specific for each patient, using the Monte-Carlo (MC) algorithm. Approach. The experimental procedure for the simulation of the treatment plans by the software was started by measuring dosimetric parameters of the operating machine (Elekta Versa HD linear accelerator), subsequently imported into the software. After that, the software tuning on the treatment planning system Monaco v. 5.53 (Elekta) was carried out, which allowed to extract the most suitable Additional Radiation to Light Field Offset parameter to obtain the best performing MC algorithm model for the simulation of the treatment plans. Finally, the above-mentioned model was validated through a statistical analysis comparing the plans recalculated by RadCalc and those experimentally verified on the OCTAVIUS 4D phantom (PTW) and Octavius 1500 (PTW) Detector. Main results. The obtained results showed a good statistical agreement both in the tuning and in the validation part of the MC algorithm model used. The effectiveness of using the RadCalc software was further demonstrated by the high accuracy of the recalculation of the MUs. Significance. It should be noted that the secondary recalculation of the dose, in accordance with Italian legislation on patient radiation protection is one of the actions that the medical physics specialist must ‘prepare for the evaluation and correct verification of the doses administered to patients’ . In this context, it has to be emphasized that a multicenter study group is being set up, within the Italian Association of Medical and Health Physics (AIFM), which brings together the users of RadCalc, aimed at exchanging experiences and improving the performance of the aforementioned software.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dipartimento di Scienze Matematiche e Informatiche, Scienze Fisiche e Scienze della Terra, Università degli Studi di Messina, V.le F. Stagno D'Alcontres 31, 98166 Messina, Italy.
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali, Università degli Studi di Messina, c/o A.O.U. Policlinico 'G. Martino'Via Consolare Valeria 1, 98125 Messina, Italy.
- U.O.C. Fisica Sanitaria, Grande Ospedale Metropolitano Bianchi Melacrino Morelli, Via G. Melacrino, 21, 89124 Reggio Calabria, Italy.
ORCID-Profile: Francesco Caridi, Giuseppe Paladini, Valentina Venuti
Zitieren
APA
Caridi, F., Paladini, G., Piccione, J., Majolino, D., Itri, B. M., Pittera, S., Sceni, G., & Venuti, V. (2026). RadCalc 3D Monte-Carlo: tuning and independent dosimetric validation of radiotherapy treatment plans. Biomedical Physics & Engineering Express, 12(6), 065029. https://doi.org/10.1088/2057-1976/aec16e
Vancouver
Caridi F, Paladini G, Piccione J, Majolino D, Itri BM, Pittera S, et al. RadCalc 3D Monte-Carlo: tuning and independent dosimetric validation of radiotherapy treatment plans. Biomedical Physics & Engineering Express. 2026;12(6):065029. doi:10.1088/2057-1976/aec16e
BibTeX
@article{Caridi2026,
author = {Caridi, Francesco and Paladini, Giuseppe and Piccione, Jacopo and Majolino, Domenico and Itri, Bruno M and Pittera, Salvatore and Sceni, Giuseppe and Venuti, Valentina},
title = {RadCalc 3D Monte-Carlo: tuning and independent dosimetric validation of radiotherapy treatment plans},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
volume = {12},
number = {6},
pages = {065029},
doi = {10.1088/2057-1976/aec16e}
}