Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants
ACS Biomaterials Science & Engineering · 2026
DOI: 10.1021/acsbiomaterials.5c01510 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, 2026. Verfasst von Rupesh Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India. Hauptthemen laut MEDLINE: Alloys, Titanium, Niobium, Prostheses and Implants. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 70 Literaturangaben.
Abstract (Originalsprache)
Titanium alloys are widely used for biomedical implants due to their favorable mechanical properties, corrosion resistance, and biocompatibility; however, their high stiffness relative to bone can lead to stress shielding. This study developed porous Ti-10Zr-xNb alloys (x = 5, 10, 15, 20 wt %) via powder metallurgy using 600 MPa cold compaction, followed by high-vacuum sealed sintering to reduce stiffness through controlled porosity. All alloys exhibited a biphasic α + β microstructure, with the β phase fraction increasing with the Nb content. The Ti-10Zr-20Nb alloy achieved the highest mechanical performance, with a compressive strength of 844.70 ± 20.92 MPa and an elastic modulus of 32.51 ± 1.52 GPa, within the modulus range of cortical bone. Electrochemical tests (OCP, EIS, PDP) conducted in simulated body fluid revealed a gradual decline in corrosion resistance with the increasing Nb content despite nearly constant porosity levels. This behavior is attributed to Nb-induced β phase stabilization and its likely influence on passive film defect chemistry, which may promote defect-assisted charge transport and reduce the barrier effectiveness of the passive film under porous conditions. Among the compositions, Ti-10Zr-5Nb exhibited the highest corrosion resistance, with Ecorr = -0.0361 V and Icorr = 17.24 μA/cm2, whereas alloys with a higher Nb content showed more negative corrosion potentials and elevated corrosion currents. Overall, Ti-10Zr-20Nb offers the best mechanical compatibility for orthopedic load-bearing implants, whereas Ti-10Zr-5Nb provides favorable electrochemical stability for dental environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India.
- Department of Automation and Robotics, Dr. D. Y. Patil Institute of Technology, Pimpri, Pune 411018, India.
- Department of Materials Engineering, Indian Institute of Science, Bengaluru 560012, India.
ORCID-Profile: Rupesh Kumar, R K Gautam
Zitieren
APA
Kumar, R., Raj, A., Pathote, D., & Gautam, R. K. (2026). Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.5c01510
Vancouver
Kumar R, Raj A, Pathote D, Gautam RK. Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants. ACS Biomaterials Science & Engineering. 2026. doi:10.1021/acsbiomaterials.5c01510
BibTeX
@article{Kumar2026,
author = {Kumar, Rupesh and Raj, Anshu and Pathote, Dileep and Gautam, R K},
title = {Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants},
journal = {ACS Biomaterials Science & Engineering},
year = {2026},
doi = {10.1021/acsbiomaterials.5c01510}
}
EUVIMED