EUVIMEDEUVIMED entdecken
EvaluationsstudieStudienprotokoll

Evaluation of revised TRS398 dosimetry protocol for pencil beam scanning proton therapy systems

Rohidas Punde iD, Dattatray Kshirsagar, Prakash Shinde iD, Kantaram Darekar iD, Lalit Chaudhari, Siddharth Laskar

Biomedical Physics & Engineering Express · 01.08.2026 · 12 (4) · 045014

DOI: 10.1088/2057-1976/ae83ba ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 09.07.2026. Verfasst von Rohidas Punde und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, B K Birla College (Empowered Autonomous status), Kalyan, Affiliated to University of Mumbai, Mumbai, India. Hauptthemen laut MEDLINE: Proton Therapy, Radiometry. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The International Atomic Energy Agency revised the TRS398 Code of Practice in 2024, incorporating dosimetry protocol for pencil beam scanning (PBS) beam delivery system with updated beam quality correction factors ( k Q , Q o ) for the majority of ionization chambers used in proton beam therapy. This study aims to evaluate the revised TRS398 protocol for dosimetry in an established isochronous cyclotron-based PBS proton therapy system and to quantify its impact on absorbed dose determination.

Methods

The reference dosimetry measurements were performed using three plane parallel ionization chambers (IBA PPC05, IBA PPC40, PTW Roos) and one cylindrical chamber (IBA FC65-G) in a water phantom on a Proteus Plus PBS proton therapy system. Uniform single-energy scanned fields (10 × 10 cm 2 ) were delivered across 33 clinical proton beam energies ranging from 70.18 MeV to 226.2 MeV. Absorbed dose to water was calculated using k Q , Q o from both the previous and revised TRS398 protocols. Ion recombination ( k s ) and polarity ( k pol ) correction factors were determined and evaluated for all chambers for 17 proton energies.

Results

The absorbed dose measurements demonstrated good inter-chamber agreement, with a maximum deviation of 2.72% at the lowest energy. Implementation of the revised k Q , Q o values resulted in mean absorbed dose differences of −1.07%, −0.66%, −0.50%, and −1.77% for the PPC05, PPC40, Roos, and FC65-G chambers, respectively, compared to the previous TRS398. The combined relative uncertainty in absorbed dose determination using the revised TRS398 was estimated to be 1.6%.

Conclusion

This study assesses the impact of the revised TRS398 dosimetry protocol on absorbed dose determination in PBS proton beams. Experimental measurements using four dosimeters in an isochronous cyclotron-based system show that the revised TRS398 provides a robust framework for PBS reference dosimetry, with the effect of updated k Q , Q o values remaining within the combined measurement uncertainty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyRadiometryHumansRadiotherapy DosagePhantoms, ImagingCyclotronsWaterRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

beam quality correction factorionization chamberpencil beam scanningproton therapyreference dosimetry

Substanzen

Water

Autor:innen und Institutionen

  • Department of Physics, B K Birla College (Empowered Autonomous status), Kalyan, Affiliated to University of Mumbai, Mumbai, India.
  • Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, India.
  • Department of Radiation Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.

ORCID-Profile: Rohidas Punde, Prakash Shinde, Kantaram Darekar

Zitieren

APA

Punde, R., Kshirsagar, D., Shinde, P., Darekar, K., Chaudhari, L., & Laskar, S. (2026). Evaluation of revised TRS398 dosimetry protocol for pencil beam scanning proton therapy systems. Biomedical Physics & Engineering Express, 12(4), 045014. https://doi.org/10.1088/2057-1976/ae83ba

Vancouver

Punde R, Kshirsagar D, Shinde P, Darekar K, Chaudhari L, Laskar S. Evaluation of revised TRS398 dosimetry protocol for pencil beam scanning proton therapy systems. Biomedical Physics & Engineering Express. 2026;12(4):045014. doi:10.1088/2057-1976/ae83ba

BibTeX
@article{Punde2026,
  author = {Punde, Rohidas and Kshirsagar, Dattatray and Shinde, Prakash and Darekar, Kantaram and Chaudhari, Lalit and Laskar, Siddharth},
  title = {Evaluation of revised TRS398 dosimetry protocol for pencil beam scanning proton therapy systems},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  volume = {12},
  number = {4},
  pages = {045014},
  doi = {10.1088/2057-1976/ae83ba}
}
Kostenlos starten →