Ultra-high-performance concrete covers with different fiber types and cover thicknesses for protecting reinforced concrete under accelerated corrosion testing
Materials Research Express · 19.11.2026
DOI: 10.1088/2053-1591/aec4a8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials Research Express, online erschienen am 19.11.2026. Verfasst von Xuan Hung Ngo und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Education and Training Ministry.
Abstract (Originalsprache)
This study investigates the effects of fiber type and cover thickness of ultra-high-performance concrete (UHPC) on rebar corrosion protection in accelerated corrosion testing. Three UHPCs with steel-fiber-reinforced (UF0.5, 0.5 vol%), glass-fiber-reinforced (UG0.5, 0.5 vol%), and stainless-steel wire mesh (UWMT2.5) were applied as 25 mm UHPC covers over reinforced concrete (RC) samples under accelerated corrosion testing in 3.5 wt% NaCl solution for 150 days. UF0.5 covers at two thicknesses (20 mm, T2.0; 25 mm, T2.5) were additionally evaluated. Performance was assessed using the rebar mass loss ratio (Mloss), six-position chloride-ion profiles spanning both the UHPC cover and the underlying substrate, the connected porosity ratio, scanning electron microscopy, and mechanical properties. UHPC covering RC substantially outperformed the RC reference (Mloss = 100 %). UHPC with wire mesh (UWMT2.5) clearly reduced Mloss (80.61 %). Glass-fiber UHPC (UG0.5T2.5, Mloss = 33.91 %) further improved protection, while steel-fiber UHPC delivered the best corrosion protection: Mloss = 23.18 % (T2.5) and 23.80 % (T2.0). The Cl- content of the steel-fiber UHPC cover was lower than that of the RC substrate and other UHPC covers. A 20 mm steel-fiber UHPC cover may be a potential cover thickness to enhance corrosion protection of RC.
Förderung
- Education and Training Ministry
Zitieren
APA
Ngo, X. H., Le, V. H., Ngo, T. H., DANG, V. P., Nguyen, L. D., Vu, Q. A., & Mai, V. C. (2026). Ultra-high-performance concrete covers with different fiber types and cover thicknesses for protecting reinforced concrete under accelerated corrosion testing. Materials Research Express. https://doi.org/10.1088/2053-1591/aec4a8
Vancouver
Ngo XH, Le VH, Ngo TH, DANG VP, Nguyen LD, Vu QA, et al. Ultra-high-performance concrete covers with different fiber types and cover thicknesses for protecting reinforced concrete under accelerated corrosion testing. Materials Research Express. 2026. doi:10.1088/2053-1591/aec4a8
BibTeX
@article{Ngo2026,
author = {Ngo, Xuan Hung and Le, Viet Huy and Ngo, Trung Hieu and DANG, Van Phi and Nguyen, Liem Duy and Vu, Quoc Anh and Mai, Viet Chinh},
title = {Ultra-high-performance concrete covers with different fiber types and cover thicknesses for protecting reinforced concrete under accelerated corrosion testing},
journal = {Materials Research Express},
year = {2026},
doi = {10.1088/2053-1591/aec4a8}
}