Design study of a ridge filter for FLASH application of proton minibeam radiotherapy
Physica Scripta · 07.08.2026 · 101 (31) · 315004
DOI: 10.1088/1402-4896/ae8ec6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 05.08.2026. Verfasst von Aikaterini Rousseti und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität der Bundeswehr München, Bundesministerium der Verteidigung.
Abstract (Originalsprache)
Objective. Over the past decade, the concepts of proton minibeam radiotherapy (pMBT) and FLASH radiotherapy have attracted attention for their ability to spare healthy tissue better than conventional radiotherapy. Investigating their combined application may further reduce treatment-related toxicity. This first proof-of-principle work investigated the feasibility of designing a ridge filter (RiFi) for a FLASH-based pMBT application. Approach. The simulations were performed in TOPAS using a 68.5 MeV magnetically focused planar proton minibeam. A RiFi was designed to generate a spread-out Bragg peak (SOBP) in a water phantom, assuming a square tumor at a depth of 2.9–3.9 cm, simplifying a pre-clinical mouse irradiation case. The RiFi consists of two separate symmetric carbon units with 10 steps of equal thickness and different widths, repeated in space perpendicular to the axis of the incident beam. The gap and the step widths are adjusted to achieve a SOBP in the target, preserving a dose variation in the tumor region of ±2%. Main results. Tumor homogeneity can be achieved for an irradiation scenario of 10 beams with a center-to-center distance of 1.4 mm. Small beam sizes can be maintained at the phantom entrance with a high peak-to-valley dose ratio. A robustness analysis revealed the sensitivity to motion of the RiFi along the x - and z - axis and the need for precise positioning to maintain dose homogeneity in the tumor. Additionally, the simulations showed that FLASH dose rates can be achieved across the entire phantom in a single beam channel. Significance. The simulation study has shown that the designed RiFi enables the generation of a SOBP with a monoenergetic incident beam in pMBT. This allows a single position of the minibeam plan to be applied in one shot, resulting in the possibility of maintaining FLASH dose rates.
Förderung
- Universität der Bundeswehr München
- Bundesministerium der Verteidigung
Zitieren
APA
Rousseti, A., Neubauer, J., & Reindl, J. (2026). Design study of a ridge filter for FLASH application of proton minibeam radiotherapy. Physica Scripta, 101(31), 315004. https://doi.org/10.1088/1402-4896/ae8ec6
Vancouver
Rousseti A, Neubauer J, Reindl J. Design study of a ridge filter for FLASH application of proton minibeam radiotherapy. Physica Scripta. 2026;101(31):315004. doi:10.1088/1402-4896/ae8ec6
BibTeX
@article{Rousseti2026,
author = {Rousseti, Aikaterini and Neubauer, Jessica and Reindl, Judith},
title = {Design study of a ridge filter for FLASH application of proton minibeam radiotherapy},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {31},
pages = {315004},
doi = {10.1088/1402-4896/ae8ec6}
}
EUVIMED