Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT
Physics in Medicine & Biology · 06.11.2026
DOI: 10.1088/1361-6560/aebf1e ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 06.11.2026. Verfasst von Rafael Carballeira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America. Hauptthemen laut MEDLINE: Particle Accelerators, Monte Carlo Method, Electrons, Radiation Dosage. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, Clinical Center, Norris Cotton Cancer Center.
Abstract (Originalsprache)
Objective: FLASH radiotherapy requires ultra-high dose rates (>40 Gy/s), yet commercial treatment planning systems are currently unavailable. Monte Carlo (MC) simulation offers high transport accuracy, but full-head modeling for every setup is computationally prohibitive. This work establishes a methodology for generating pulse-width-specific phase-space files for the Mobetron UHDR (9 MeV), accounting for systematic beam quality shifts caused by RF waveguide loading across pulse widths of 1.2-4.0 μs. 
Approach: Using GAMOS 6.2.0 MC simulations, voxelized dose distributions were post-processed via an iterative script to refine source-level parameters against experimental targets. Mean energy was optimized by matching phantom-measured R50, while energy spread was refined using surface dose and build-up gradients. Relationships derived from a mid-range 6 cm applicator were applied across clinical apertures (2.5-10 cm) to test aperture-independence. The geometric mean of experimental pulse widths (2.28 μs) was evaluated as a single reference condition. 
Main Results: Phase space files were generated across pulse widths and apertures. For the A6I6 reference, mean energy decreased monotonically from 9.58±0.24 to 9.04±0.24 MeV with pulse width, best described by a logarithmic model (LOO-RMSE=0.033 MeV). Energy spread increased linearly from 0.173±0.020 to 0.287±0.020 MeV (LOO-RMSE=0.005 MeV). Cross-aperture validation confirmed these shifts occur upstream of collimation. Evaluating the 2.28 μs reference predicted 9.30 MeV mean energy and 0.215 MeV energy spread, yielding depth-dose deviations ≤1.3 mm across experimental extremes and satisfying AAPM TG-106 tolerances (≤2.0 mm). 
Significance: This work provides pulse-width-specific phase-space characterization for Mobetron FLASH commissioning. Cross-validated regression models enable beam parameter prediction within 1.2-4.0 μs, and the 2.28 μs reference phase space streamlines routine planning while maintaining clinical accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America.
- Dartmouth Cancer Center, Lebanon, NH, United States of America.
- IntraOp Medical Corporation, Sunnyvale, CA, United States of America.
- School of Medicine, University of Missouri, Columbia, MO, United States of America.
ORCID-Profile: Rafael Carballeira, David J Gladstone, Kevin J Willy, Philip Von-Voigts Rhetz, Rongxiao Zhang
Förderung
- NCI NIH HHS
- Clinical Center
- Norris Cotton Cancer Center
Zitieren
APA
Carballeira, R., Gladstone, D. J., Willy, K. J., Von-Voigts Rhetz, P., & Zhang, R. (2026). Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/aebf1e
Vancouver
Carballeira R, Gladstone DJ, Willy KJ, Von-Voigts Rhetz P, Zhang R. Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT. Physics in Medicine & Biology. 2026. doi:10.1088/1361-6560/aebf1e
BibTeX
@article{Carballeira2026,
author = {Carballeira, Rafael and Gladstone, David J and Willy, Kevin J and Von-Voigts Rhetz, Philip and Zhang, Rongxiao},
title = {Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT},
journal = {Physics in Medicine & Biology},
year = {2026},
doi = {10.1088/1361-6560/aebf1e}
}
EUVIMED