Validierungsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 11.06.2026. Verfasst von Zhixin Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Imaging, Fujian Medical University, Fuzhou, China. Hauptthemen laut MEDLINE: Particle Accelerators, Monte Carlo Method, Electrons, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fujian Provincial Department of Science and Technology, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
In Monte Carlo (MC) simulations of medical electron linear accelerator (linac) rooms using FLUKA, time‐consuming modeling and simulation of the accelerator head are typically required, and FLUKA cannot directly read the phase space files (PSF) for accelerator heads provided by the IAEA. To address this, this study aimed to establish and validate the accuracy of a radiation model for an accelerator room within FLUKA using a virtual source, thereby enhancing the applicability of FLUKA for the design and evaluation of rooms housing different medical electron linacs.
Methods
The 6 MV photon beam from a Varian 23EX linac was modeled as consisting of primary photons, scattered photons, and contaminant electrons. Their energy spectra and spatial distributions were represented by mathematical formulas. Python code was used to sample particle information (type, position, direction, energy, weight) from this mathematically defined virtual source, generating a FLUKA‐readable PSF. A room radiation model was then established in FLUKA. Its accuracy was validated by comparing simulated and measured percentage depth dose (PDD) and off‐axis ratios (OAR) in a water tank, as well as comparing simulated and measured dose equivalent rates at selected points inside the accelerator room.
Results
The deviation between simulated and measured PDD was within 1%, and that for the OAR was within 2%. At gantry angles of 0° and 90° (with the head oriented toward the maze inner entrance), the simulated dose‐equivalent rates at the points of interest inside the treatment room closely agreed with the measured values.
Conclusion
The phase‐space file sampled from the virtual source can faithfully reproduce the beam characteristics in FLUKA. The agreement between simulation and measurement at the points of interest demonstrates that the room radiation model established in FLUKA using the virtual source accurately reflects the actual radiation field in the treatment room. This approach replaces the need for simulating the accelerator head model and improves the efficiency of using FLUKA for radiation protection studies on rooms equipped with different medical electron linear accelerators.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medical Imaging, Fujian Medical University, Fuzhou, China.
- Department of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou, China.
- Manteia Data Technology Co., Ltd, Xiamen, China.
- Fujian Center for Prevention and Control of Occupational Diseases and Chemical Poisoning, Fuzhou, China.
Förderung
- Fujian Provincial Department of Science and Technology
- National Natural Science Foundation of China
Zitieren
APA
Wang, Z., Jiang, L., Sheng, H., Zhou, Q., Zheng, S., & Li, X. (2026). Establishment and validation of a FLUKA radiation model for a medical electron linear accelerator room based on a virtual source. Journal of Applied Clinical Medical Physics, 27(6). https://doi.org/10.1002/acm2.70647
Vancouver
Wang Z, Jiang L, Sheng H, Zhou Q, Zheng S, Li X. Establishment and validation of a FLUKA radiation model for a medical electron linear accelerator room based on a virtual source. Journal of Applied Clinical Medical Physics. 2026;27(6). doi:10.1002/acm2.70647
BibTeX
@article{Wang2026,
author = {Wang, Zhixin and Jiang, Liuqing and Sheng, Huashan and Zhou, Qichao and Zheng, Senxing and Li, Xiaobo},
title = {Establishment and validation of a FLUKA radiation model for a medical electron linear accelerator room based on a virtual source},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {6},
doi = {10.1002/acm2.70647}
}
EUVIMED