Decoupling the dosimetric impact of setup errors and anatomical deformations in image-guided radiotherapy using diagnostic-quality FBCT and glmmLasso regularization

Lianzi Zhao, Ying Guo, Yuanshuai Di iD, Haowen Yang, Louzheng Zhang, Dadi Gao, Weigang Hu, Qing Xu, Wei Lu, Yang Zhong iD

Physics in Medicine & Biology · 28.08.2026 · 71 (16) · 165014

DOI: 10.1088/1361-6560/ae95aa ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 20.08.2026. Verfasst von Lianzi Zhao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, People's Republic of China. Hauptthemen laut MEDLINE: Radiotherapy, Image-Guided, Radiotherapy Setup Errors, Tomography, X-Ray Computed. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Traditional radiotherapy dosimetric analyses are often limited by cone-beam CT artifacts and correlated longitudinal data mismanagement. This study uses artifact-free fan-beam CT (FBCT) and a generalized linear mixed Lasso (glmmLasso) model to decouple interfraction setup errors and anatomical deformations within a simulated image-guided radiotherapy workflow, providing quantitative support for future site-specific ART research. Approach. We retrospectively analyzed 84 patients (head and neck [H&N], thorax, pelvis; n = 28 each). Weekly diagnostic-quality FBCTs served as ground truth. To isolate error sources, we recalculated 1 260 dose distributions under three scenarios: isolated setup errors, isolated deformations, and combined effects. A glmmLasso model, using patient-specific random intercepts and L1 penalization, identified the primary geometric drivers of dosimetric variation. Main Results. H&N exhibited minimal setup deviations (< 2.0 mm); dosimetric variance was driven by inter-patient baseline heterogeneity (ICC > 0.73) rather than interfraction deformations. Thoracic setup uncertainties (mean≈4.0 mm) reduced minimum target dose up to 50% for displacements ⩾ 5 mm, but overall variance was primarily governed by non-rigid deformations (marginal R 2 = 0.423). Pelvic anatomy demonstrated pronounced variability due to bladder filling (DSC: 0.2–0.9), and the coupled scenario further amplified relative deviations in bladder and femoral-head dose metrics. Significance. Utilizing FBCT and high-dimensional feature selection, we decoupled site-specific drivers of dosimetric variation. Quantifying these coupled effects establishes a robust, validated foundation for tailored potential factors to inform ART decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Image-GuidedRadiotherapy Setup ErrorsTomography, X-Ray ComputedHumansRadiometryRadiotherapy DosageRetrospective StudiesRadiotherapy Planning, Computer-AssistedCone-Beam Computed TomographyLinear Models

Stichwörter der Autor:innen

anatomical deformationsfan-beam ctglmmLassoimage-guided radiotherapysetup errors

Autor:innen und Institutionen

  • Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, People's Republic of China.
  • Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, People's Republic of China.
  • Shanghai Clinical Research Center for Radiation Oncology, Shanghai 200032, People's Republic of China.
  • Shanghai Key Laboratory of Radiation Oncology, Shanghai 200032, People's Republic of China.

ORCID-Profile: Yuanshuai Di, Yang Zhong

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhao, L., Guo, Y., Di, Y., Yang, H., Zhang, L., Gao, D., Hu, W., Xu, Q., Lu, W., & Zhong, Y. (2026). Decoupling the dosimetric impact of setup errors and anatomical deformations in image-guided radiotherapy using diagnostic-quality FBCT and glmmLasso regularization. Physics in Medicine & Biology, 71(16), 165014. https://doi.org/10.1088/1361-6560/ae95aa

Vancouver

Zhao L, Guo Y, Di Y, Yang H, Zhang L, Gao D, et al. Decoupling the dosimetric impact of setup errors and anatomical deformations in image-guided radiotherapy using diagnostic-quality FBCT and glmmLasso regularization. Physics in Medicine & Biology. 2026;71(16):165014. doi:10.1088/1361-6560/ae95aa

BibTeX
@article{Zhao2026,
  author = {Zhao, Lianzi and Guo, Ying and Di, Yuanshuai and Yang, Haowen and Zhang, Louzheng and Gao, Dadi and Hu, Weigang and Xu, Qing and Lu, Wei and Zhong, Yang},
  title = {Decoupling the dosimetric impact of setup errors and anatomical deformations in image-guided radiotherapy using diagnostic-quality FBCT and glmmLasso regularization},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {16},
  pages = {165014},
  doi = {10.1088/1361-6560/ae95aa}
}
Kostenlos starten →