Dosimetry evaluation of an MRI guided small animal irradiator

Cheng Zheng iD, Xiaogang Yuan iD, Yaowen Cao iD, Ning Zhao, Yidong Yang iD

Physics in Medicine & Biology · 14.08.2026 · 71 (15) · 155025

DOI: 10.1088/1361-6560/ae8fb2 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Physics in Medicine & Biology, online erschienen am 07.08.2026. Verfasst von Cheng Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, People's Republic of China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Radiotherapy, Image-Guided, Radiometry. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, Ministry of Science and Technology of China Key Research and Development Projects, Hefei Comprehensive National Science Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Magnetic Resonance guided Radiation Therapy (MRgRT) integrates magnetic resonance imaging with radiation delivery, providing superior soft-tissue contrast and real-time treatment guidance. For preclinical MRgRT irradiators, a critical concern is whether the ambient magnetic fields compromise the radiation dose distribution. This study aims to investigate the influence of magnetic fields on X-ray tube electron trajectories and dosimetric outcomes. Approach. The system integrates a 0.5 T MRI scanner and a 225 kVp X-ray tube. The local magnetic field distribution was characterized via finite element analysis. Electron trajectories were simulated across various magnetic field strengths and alignment angles to quantify the X-ray focal-spot displacement. Monte Carlo simulation was then performed to evaluate the dose distribution within homogeneous and heterogeneous tissue-equivalent phantoms. Main results. In the proposed system, the fringe magnetic field across the X-ray tube electrodes measures 40.4 G and aligns nearly parallel to the electric field. This configuration restricts the X-ray focal-spot displacement to 0.15 mm, resulting in negligible dosimetric deviations. There is good agreement between the dose distributions in the phantoms with and without magnetic fields, maintaining ⩾ 99.9 % gamma passing rates at 0.5 mm / 1% criteria even under a main magnetic field of up to 10 T. Significance. This study confirms that, for the small animal MRgRT system, main magnetic field as low as 0.5 T exerts no significant dosimetric impact, provided the magnet and the X-ray tube are well separated, and it may be unnecessary to perform dosimetric corrections.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRadiotherapy, Image-GuidedRadiometryAnimalsMonte Carlo MethodPhantoms, ImagingMagnetic FieldsRadiotherapy Dosage

Stichwörter der Autor:innen

MRgRTMonte Carlo simulationdosimetrysmall animal irradiator

Autor:innen und Institutionen

  • Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.
  • Raycision Medical Technology Co. Ltd, Hefei, Anhui, People's Republic of China.
  • Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.
  • Ion Medical Research Institute, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.

ORCID-Profile: Cheng Zheng, Xiaogang Yuan, Yaowen Cao, Yidong Yang

Förderung

  • Fundamental Research Funds for the Central Universities
  • Ministry of Science and Technology of China Key Research and Development Projects
  • Hefei Comprehensive National Science Center

Zitieren

APA

Zheng, C., Yuan, X., Cao, Y., Zhao, N., & Yang, Y. (2026). Dosimetry evaluation of an MRI guided small animal irradiator. Physics in Medicine & Biology, 71(15), 155025. https://doi.org/10.1088/1361-6560/ae8fb2

Vancouver

Zheng C, Yuan X, Cao Y, Zhao N, Yang Y. Dosimetry evaluation of an MRI guided small animal irradiator. Physics in Medicine & Biology. 2026;71(15):155025. doi:10.1088/1361-6560/ae8fb2

BibTeX
@article{Zheng2026,
  author = {Zheng, Cheng and Yuan, Xiaogang and Cao, Yaowen and Zhao, Ning and Yang, Yidong},
  title = {Dosimetry evaluation of an MRI guided small animal irradiator},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {15},
  pages = {155025},
  doi = {10.1088/1361-6560/ae8fb2}
}
Kostenlos starten →