Fast water/fat T 2 and PDFF mapping via multiple overlapping-echo detachment acquisition and deep learning reconstruction
Physics in Medicine & Biology · 2025
DOI: 10.1088/1361-6560/ae0efa ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von Qing Lin und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen 361105, People's Repub…. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Water, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Guangdong Basic and Applied Basic Research Foundation.
Abstract (Originalsprache)
Objective. Rapid and accurate quantitative assessment of muscle tissue characteristics is valuable for the diagnosis and monitoring of neuromuscular diseases (NMDs). Quantitative magnetic resonance imaging (MRI) enables non-invasive assessment of muscle pathology by using water T 2 values to assess muscle damage and proton density fat fraction (PDFF) to quantify fat infiltration. However, conventional methods for simultaneous water-fat separation and T 2 quantification often require long acquisition times. This study aims to develop an ultrafast method for simultaneous water-fat separation and T 2 quantification. Approach. A novel water-fat separation framework that combines chemical shift encoding with the multiple overlapping-echo detachment sequence (CSE-MOLED) was proposed. Synthetic training data and deep learning-based reconstruction were employed to address challenges in water-fat separation, including the complex multi-peak spectral characteristic of fat and the non-idealities in MRI acquisition. All experiments, including phantom and in vivo scans, were performed on a 3T MRI scanner. The in vivo experiments focused on the human thigh and involved five healthy volunteers, one subject with muscle atrophy, and one with muscle damage. The CSE-MOLED sequence was acquired with a spatial resolution of 1.72 mm × 1.72 mm × 5 mm. For reference, mDixon-TSE (Turbo Spin Echo) was performed to generate PDFF, water T 2 , and fat T 2 maps. Main results. In numerical experiments ( T 2 range: water 19–160 ms, fat 15–160 ms; PDFF range: 14%–100%), the R 2 values were all 0.999 for water T 2 , fat T 2 , and PDFF, with average percentage errors of 3.16%, 0.98%, and 0.78%, respectively. In phantom experiments ( T 2 range: water 35–125 ms, fat 36–47 ms; PDFF range: 14–36%), the R 2 values were 0.995, 0.733, and 0.996 for water T 2 , fat T 2 , and PDFF, with average percentage errors of 5.56%, 2.93%, and 1.77%, respectively. High repeatability (coefficient of variation
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen 361105, People's Republic of China.
- Department of Magnetic Resonance Center, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen 361004, People's Republic of China.
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, United States of America.
- Department of Radiology, Harvard Medical School, Boston, MA 02115, United States of America.
- Clinical and Technical Solutions, Philips Healthcare, Beijing 100125, People's Republic of China.
- Shenzhen Research Institute of Xiamen University, Shenzhen 518057, People's Republic of China.
ORCID-Profile: Qing Lin, Jian Wu, Xinran Chen, Shuhui Cai, Congbo Cai
Förderung
- National Key R&D Program of China
- National Natural Science Foundation of China
- Guangdong Basic and Applied Basic Research Foundation
- National Key Research and Development Program of China
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Lin, Q., Chen, W., Kang, T., Wu, J., Chen, X., Qu, X., Lin, L., Wang, J., Lin, J., Chen, Z., Cai, S., & Cai, C. (2025). Fast water/fat T 2 and PDFF mapping via multiple overlapping-echo detachment acquisition and deep learning reconstruction. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ae0efa
Vancouver
Lin Q, Chen W, Kang T, Wu J, Chen X, Qu X, et al. Fast water/fat T 2 and PDFF mapping via multiple overlapping-echo detachment acquisition and deep learning reconstruction. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/ae0efa
BibTeX
@article{Lin2025,
author = {Lin, Qing and Chen, Weikun and Kang, Taishan and Wu, Jian and Chen, Xinran and Qu, Xiaobo and Lin, Liangjie and Wang, Jiazheng and Lin, Jianzhong and Chen, Zhong and Cai, Shuhui and Cai, Congbo},
title = {Fast water/fat T 2 and PDFF mapping via multiple overlapping-echo detachment acquisition and deep learning reconstruction},
journal = {Physics in Medicine & Biology},
year = {2025},
doi = {10.1088/1361-6560/ae0efa}
}
EUVIMED