Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics
Physics in Medicine & Biology · 2025
DOI: 10.1088/1361-6560/ada19a ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von Giulia Terragni und 10 weiteren Autor:innen. Beteiligte Einrichtung: CERN, Geneva, Switzerland. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Electronics. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective. Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a 4 × 4 3.1 × 3.1 × 15 mm 3 LYSO:Ce matrix with an array of 4 × 4 silicon photomultipliers (SiPMs) and a light guide to extract high-resolution TOF and depth of interaction (DOI) information. Approach. This study assesses the performance of the detector prototype using the commercially available TOFPET2 ASIC and SiPMs from various producers. DOI and TOF performance are compared to results using custom-made NINO 32-chip based electronics. Main results. Using a Broadcom NUV-MT array, the detector module read out by the TOFPET2 ASIC demonstrates a DOI resolution of 2.6 ± 0.2 mm full width at half maximum (FWHM) and a coincidence time resolution (CTR) of 216 ± 6 ps FWHM. When read out using the NINO 32-chip based electronics, the same module achieves a DOI resolution of 2.5 ± 0.2 mm and a CTR of 170 ± 5 ps. Significance. The prototype module, read out by commercial electronics and using state-of-the-art SiPMs, achieves a DOI performance comparable to that obtained with custom-made electronics and a CTR of around 200 ps. This approach is scalable to thousands of channels, with only a deterioration in timing resolution compared to the custom-made electronics, which achieve a CTR of 140 ps using a standard non-DOI module.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CERN, Geneva, Switzerland.
- Technical University of Vienna, Vienna, Austria.
- Department of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
- University of Milano-Bicocca, Milan, Italy.
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany.
- Physics Institute IIIB, RWTH Aachen University, Aachen, Germany.
ORCID-Profile: Giulia Terragni, Vanessa Nadig, Thomas Meyer, Johann Marton, Stefan Gundacker, Marco Pizzichemi, Etiennette Auffray
Zitieren
APA
Terragni, G., Nadig, V., Tribbia, E., di Gangi, S., Toumparidou, E., Meyer, T., Marton, J., Schulz, V., Gundacker, S., Pizzichemi, M., & Auffray, E. (2025). Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ada19a
Vancouver
Terragni G, Nadig V, Tribbia E, di Gangi S, Toumparidou E, Meyer T, et al. Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/ada19a
BibTeX
@article{Terragni2025,
author = {Terragni, Giulia and Nadig, Vanessa and Tribbia, Elena and di Gangi, Stefano and Toumparidou, Ekaterini and Meyer, Thomas and Marton, Johann and Schulz, Volkmar and Gundacker, Stefan and Pizzichemi, Marco and Auffray, Etiennette},
title = {Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics},
journal = {Physics in Medicine & Biology},
year = {2025},
doi = {10.1088/1361-6560/ada19a}
}