Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Jackson W Foster und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Image Processing, Computer-Assisted. Die Arbeit nennt 40 Literaturangaben. Gefördert von: NCI NIH HHS, Dr. Ralph and Marian Falk Medical Research Trust, Stanford Bio-X.
Abstract (Originalsprache)
Background
Multiplexed PET ( m PET) using one tracer labeled with a positron plus prompt gamma ray emitter is limited by low sensitivity to triple‐photon coincidences (two annihilation photons and one prompt gamma photon), leading to high noise in the reconstructed images.
Purpose
The use of regularization has been previously shown to increase the image quality of single tracer PET images under low signal‐to‐noise ratio conditions. We will demonstrate the use of regularization in simultaneously acquired multi‐tracer m PET data reconstruction.
Methods
First, we present how a maximum a posteriori expectation maximization solution can be obtained for simultaneously acquired multi‐isotope PET data. Next, we use a Monte Carlo simulation of an image quality phantom m PET acquisition with a pure positron ( 18 F) and a positron plus prompt gamma ( 44 Sc) emitter to evaluate the performance of different regularization methods.
Results
For a baseline regularization method to simultaneously reconstruct both activity distributions, we show that a relative difference penalty (RDP) provides the best tradeoff of the penalty functions tested in image quality and quantitative accuracy for a simulated hot sphere phantom compared to quadratic and log‐cosh penalty functions, with a contrast‐to‐noise ratio (CNR) in 18 F/ 44 Sc of over 60% higher on average for the RDP compared to the quadratic penalty in the largest spheres. However, this regularization approach has up to 2x worse reconstructed inter‐tracer crosstalk ratio compared to unregularized reconstruction. Finally, we present a further optimization by alternating reconstruction of the two individual tracer images with regularization to achieve a CNR in the largest 18 F/ 44 Sc spheres with an up to 35% improvement on average over the simultaneous RDP‐based regularization reconstruction results described above, while maintaining a 10%–20% lower inter‐tracer crosstalk ratio over the unregularized reconstruction.
Conclusions
For the selected radionuclides, simulated system and phantom, we demonstrate proof‐of‐principle that using regularization applied to an alternating update form of EM achieves significantly higher CNR in both tracers compared to unregularized alternating update OSEM and regularized simultaneous OSEM, with significantly lower crosstalk in the prompt gamma emitter reconstruction than the regularized simultaneous OSEM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.
- Molecular Imaging Program, Department of Radiology, Stanford University, Stanford, California, USA.
- Department of Bioengineering, Stanford University, Stanford, California, USA.
- Department of Physics, Stanford University, Stanford, California, USA.
Förderung
- NCI NIH HHS
- Dr. Ralph and Marian Falk Medical Research Trust
- Stanford Bio-X
- Society of Nuclear Medicine and Molecular Imaging - Mars Shot
- National Science Foundation
Zitieren
APA
Foster, J. W., He, W., Chinn, G., & Levin, C. S. (2026). Regularization in multiplexed PET image reconstruction. Medical Physics. https://doi.org/10.1002/mp.70738
Vancouver
Foster JW, He W, Chinn G, Levin CS. Regularization in multiplexed PET image reconstruction. Medical Physics. 2026. doi:10.1002/mp.70738
BibTeX
@article{Foster2026,
author = {Foster, Jackson W and He, Wen and Chinn, Garry and Levin, Craig S},
title = {Regularization in multiplexed PET image reconstruction},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70738}
}
EUVIMED