EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Investigation of TL and OSL detectors in ultra-high dose rate electron beams

S Motta iD, J B Christensen iD, F Frei, P Peier, E G Yukihara iD

Physics in Medicine & Biology · 21.07.2023 · 68 (14) · 145007

DOI: 10.1088/1361-6560/acdfb2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 11.07.2023. Verfasst von S Motta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Safety and Security, Paul Scherrer Institute, Villigen PSI, Switzerland. Hauptthemen laut MEDLINE: Electrons, Radiometry. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Eidgenössisches Nuklearsicherheitsinspektorat.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. This work aims at investigating the response of various thermally stimulated luminescence detectors (TLDs) and optically stimulated luminescence detectors (OSLDs) for dosimetry of ultra-high dose rate electron beams. The study was driven by the challenges of dosimetry at ultra-high dose rates and the importance of dosimetry for FLASH radiotherapy and radiobiology experiments. Approach. Three types of TLDs (LiF:Mg,Ti; LiF:Mg,Cu,P; CaF 2 :Tm) and one type of OSLD (Al 2 O 3 :C) were irradiated in a 15 MeV electron beam with instantaneous dose rates in the (1–324) kGy s −1 range. Reference dosimetry was carried out with an integrating current transformer, which was calibrated in absorbed dose to water against a reference ionization chamber. Additionally, dose rate independent BeO OSLDs were employed as a reference. Beam non-uniformity was addressed using a matrix of TLDs/OSLDs. Main results. The investigated TLDs were shown to be dose rate independent within the experimental uncertainties, which take into account the uncertainty of the dosimetry protocol and the irradiation uncertainty. The relative deviation between the TLDs and the reference dose was lower than 4 % for all dose rates. A decreasing response with the dose rate was observed for Al 2 O 3 :C OSLDs, but still within 10 % from the reference dose. Significance. The precision of the investigated luminescence detectors make them suitable for dosimetry of ultra-high dose rate electron beams. Specifically, the dose rate independence of the TLDs can support the investigation of the beam uniformity as a function of the dose rate, which is one of the challenges of the employed beam. Al 2 O 3 :C OSLDs provided high precision measurements, but the decreasing response with the dose rate needs to be confirmed by additional experiments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectronsRadiometryLuminescenceWater

Stichwörter der Autor:innen

FLASH dosimetrydose rate dependenceoptically stimulated luminescence dosimetrythermoluminescence dosimetry

Substanzen

Water

Autor:innen und Institutionen

  • Department of Radiation Safety and Security, Paul Scherrer Institute, Villigen PSI, Switzerland.
  • Department of Physics, ETH Zürich, Zürich, Switzerland.
  • Laboratory of Ionising Radiation, Federal Institute of Metrology, Bern, Switzerland.

ORCID-Profile: S Motta, J B Christensen, E G Yukihara

Förderung

  • Eidgenössisches Nuklearsicherheitsinspektorat

Zitieren

APA

Motta, S., Christensen, J. B., Frei, F., Peier, P., & Yukihara, E. G. (2023). Investigation of TL and OSL detectors in ultra-high dose rate electron beams. Physics in Medicine & Biology, 68(14), 145007. https://doi.org/10.1088/1361-6560/acdfb2

Vancouver

Motta S, Christensen JB, Frei F, Peier P, Yukihara EG. Investigation of TL and OSL detectors in ultra-high dose rate electron beams. Physics in Medicine & Biology. 2023;68(14):145007. doi:10.1088/1361-6560/acdfb2

BibTeX
@article{Motta2023,
  author = {Motta, S and Christensen, J B and Frei, F and Peier, P and Yukihara, E G},
  title = {Investigation of TL and OSL detectors in ultra-high dose rate electron beams},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  volume = {68},
  number = {14},
  pages = {145007},
  doi = {10.1088/1361-6560/acdfb2}
}
Kostenlos starten →